STA-RITE Dura Jet JSACLC-A Owner'S Manual Download Page 5

5

ELECTRICAL

Ground motor before connecting to electrical power supply! Failure to
ground pump motor can cause serious or fatal electrical shock hazard!

Do not ground to a gas supply line!

To avoid dangerous or fatal electrical shock, turn OFF power to motor
before working on electrical connections.

GFCI tripping indicates an electrical problem. If GFCI trips and will not
reset, have a qualified electrician inspect and repair electrical system.

Exactly match supply voltage to nameplate voltage (115 Volt or 230
Volt single phase only)! Incorrect voltage can cause fire or seriously

damage motor and voids warranty!

Grounding:

Install, ground, and wire motor according to local or National Electrical Code
requirements.
Permanently ground motor; use size and type wire required by code.
Ground connection must be made to green grounding terminal under motor
canopy or access plate (see Figure 1).
Connect motor ground terminal to electrical service ground.
Install and bond pump according to local codes and ordinances; use bonding
lug on motor (see Figure 1). Use solid copper conductor No. 8 AWG (8.4mm

2

)

or larger.

Wiring:

Pump must be permanently connected to circuit. Table I, Page 6, gives correct
wire and circuit breaker sizes for the pump alone. If other lights or appliances
are also on the same circuit, be sure to add their amp loads to pump amp load
before figuring wire and circuit breaker sizes. (If unsure how to do this or if
this is confusing, consult a licensed electrician.) Use the load circuit breaker
as the master on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit; it will sense a short-
circuit to ground and disconnect power before it becomes dangerous to pool
users. For size of GFCI required and test procedures for GFCI, see manufac-
turer’s instruction.
In case of power outage, check GFCI for tripping (which will prevent normal
pump operation). Reset if necessary. 

NOTICE: 

If you do not use conduit when wiring motor, 

be sure

to seal wire

opening on end of motor to prevent dirt, bugs, etc., from entering.

Hazardous voltage.
Can shock, burn,
or cause death.

Ground pump before
connecting to
power supply.

BONDING

LUG

MOTOR NAMEPLATE

GREEN

GROUND

SCREW

MOTOR

CANOPY

THROUGH

BOLTS

White 

230
Volt
Lines

A

B

L2

L1

Blue

SINGLE

VOLTAGE

MOTORS

DUAL

VOLTAGE

MOTORS

A

B

L2

L1

White
w/Black 
Tracer

Black

115
Volt
Lines

A

B

L2

L1

White
w/Black 
Tracer

Black

230
Volt
Lines

Motor Terminal Board Connections

A: Typical ground screw and bonding
lug locations.

Figure 1 – Electrical connections;
motor terminal  block and bonding.

B. Motor terminal block connections.

Summary of Contents for Dura Jet JSACLC-A

Page 1: ...SAYELC LA JSAEFLC A JSAYFLC 230A JSYE 100 JSYF 150 Sta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 International 262 728 5551 FAX 262 728 7550 www starite com Union City TN Delavan WI Missi...

Page 2: ...he Sta Rite JT Series Tub Pump Is designed to circulate hot water in jetted tubs Is an excellent performer durable reliable Drains completely to assure sanitation meet IAPMO standards Table of Content...

Page 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Relea...

Page 4: ...Piping Use flexible or rigid PVC pipe for connections to pump Use at least 1 1 2 IPS pipe Fittings restrict flow for best efficiency use fewest possible fittings Unions are provided Use as follows for...

Page 5: ...rect wire and circuit breaker sizes for the pump alone If other lights or appliances are also on the same circuit be sure to add their amp loads to pump amp load before figuring wire and circuit break...

Page 6: ...OMMENDED CIRCUIT BREAKER SIZE AND WIRING DATA FOR 60 Hz MOTORS Branch AWG mm2 Wire Gauge Size Full Circuit Dist in Ft M Service to Motor Model Motor Load Breaker 0 100 101 200 201 300 Temp No HP Volts...

Page 7: ...erature and gradually increase it according to your experience Keep an accurate thermometer in bath check it before getting in Do not use or allow the use of the tub by anyone using alcohol or drugs T...

Page 8: ...e ring seats and seals 6 Carefully remove four motor throughbolts from seal plate Figure 3 remove seal plate and use a screwdriver to tap ceramic seat out from the rear Figure 4 Do not damage seal cav...

Page 9: ...f possible store chemicals in another room Allowing pump to freeze will damage pump and void warranty Drain all water from pump and piping when expecting freezing temperatures or when storing pump for...

Page 10: ...3 Not illustrated JSAFLC A JSAEFLC A only REPAIR PARTS LIST DURA JETTM and MAX E JETTM SPA PUMP 1 2 through 1 1 2 HP Models Parts are common to all models listed except as noted Key Nos 1 Motor and 9...

Page 11: ...s Blocked fittings will cause poor flow and poor jet action 2 Consult dealer installer or service representative C EXCESSIVE AIR IN SYSTEM PUMP LOSES PRIME 1 Make sure water level in spa is at least 2...

Page 12: ...lbs ac cessories and fittings manufactured by Sta Rite are warranted to be free of defects in material and or workmanship for one 1 year from the original date of installation The foregoing warranties...