background image

10

3. Remove strainer basket and clean. Be sure all holes in basket are clear,

flush basket with water and replace in trap with large opening at pipe con-
nection port (between ribs provided). If basket is replaced backwards cover
will not fit on trap body.

4. Clean and inspect lid O-Ring; reinstall on trap cover.
5. Clean O-Ring groove on trap body and replace lid. To help keep lid from

sticking, tighten 

hand tight only (no wrenches!)

.

6. Prime pump (see priming instructions).

Draining Pump

1. Pump down water level below all inlets to the pool.

To avoid dangerous or fatal electrical shock hazard, turn OFF power to

motor before draining pump.

2. Remove trap cover and use low pressure air to blow accumulated water

from the piping system. Lugs have been provided on the trap lid to use a
lever or pry bar for loosening.

3. Cap inlet piping after draining to keep water out of the pipes.
4. To prevent pump from freezing, remove trap cover and drain the tank body

through the drain plugs (Key No. 19, Pages 14 - 18). Clean pump and trap
basket thoroughly; replace trap cover.

NOTICE: 

Tighten trap cover by hand only 

(no wrenches)! 

Use a lever or

wrench only if necessary to remove cover! If pump is not anchored, use
caution not to break attached piping!

5. Be sure motor is kept dry and covered.

Storage/Winterizing:

Explosion hazard. Purging the system with compressed air can

cause components to explode, with risk of severe injury or death to anyone
nearby.

Use only a low pressure (below 5 PSI), high volume blower when air

purging the pump, filter, or piping.

NOTICE: 

Allowing pump to freeze will damage pump and void warranty!

NOTICE: Do not 

use anti-freeze solutions (except propylene glycol) in your

pool/spa system. Propylene glycol is non-toxic and will not damage plastic
system components; other anti-freezes are highly toxic and may damage plas-
tic components in the system.
Drain all water from pump and piping when expecting freezing temperatures
or when storing pump for a long time (see instructions below).
Keep motor dry and covered during storage.
To avoid condensation/corrosion problems, 

do not 

cover pump with plastic.

For outdoor/unprotected installations:
1. Gravity drain system as far as possible.
2. Protect areas which retain water with non-toxic propylene glycol antifreeze

(“RV antifreeze”).

3. Enclose entire system in a weatherproof enclosure.
4. To avoid condensation/corrosion damage, allow ventilation; 

do not 

wrap

system in plastic.

5. Use a 40% propylene glycol/60% water solution to protect pump to -50°F

(-46°C).

Hazardous voltage.
Can shock, burn,
or cause death.

Disconnect power
before working
on pump or motor.

Summary of Contents for DURA-GLAS II

Page 1: ...ght Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 www sta ritepool com Union City TN Delavan WI Mississauga Ont Murr...

Page 2: ...oting Guide 13 Repair Parts List 14 18 Warranty 19 Max E Glas II HP 3 4 P4E6D 186L P4E62D 186L P4E6D 186LV 1 P4E6E 187L P4EA6E 186L P4E62E 187L P4E6E 187LV 1 1 2 P4E6F 188L P4EA6F 187L P4E62F 188L P4E...

Page 3: ...sion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing R...

Page 4: ...g pump and piping Fire and burn hazard Modern motors run at high temperatures To reduce the risk of fire do not allow leaves debris or foreign matter to col lect around the pump motor To avoid burns w...

Page 5: ...PUMP SUCTION REQUIREMENTS Pump suction is hazardous and can trap and drown or disem bowel bathers Do not use or operate swimming pools spas or hot tubs if a suction outlet cover is missing broken or...

Page 6: ...ot exceed the suction fittings maxi mum designed flow rate If 100 of the pump s flow comes from the main drain system the maximum water velocity in the pump suction hydraulic system must be six feet p...

Page 7: ...mes dangerous to pool users For size of GFCI required and test procedures for GFCI see manufac turer s instructions In case of power outage check GFCI for tripping which will prevent normal water circ...

Page 8: ...11 5 5 8 230 460 60 3 14 2 14 2 12 3 14 2 Time delay fuses are recommended instead of standard fuses in any motor circuit Wire Size AWG mm2 Wire Size AWG mm2 Wire Size AWG mm2 Wire Size AWG mm2 Wire...

Page 9: ...prime itself when suction and discharge valves are opened If pump is not in a flooded suction system unscrew and remove trap cover fill trap and pump with water Do not lubricate the trap cover O Ring...

Page 10: ...ion not to break attached piping 5 Be sure motor is kept dry and covered Storage Winterizing Explosion hazard Purging the system with compressed air can cause components to explode with risk of severe...

Page 11: ...pump is operating To avoid dangerous or fatal electrical shock hazard turn OFF power to motor before working on pump or motor Aside from lubricating trap cover O Ring no lubrication or regular mainte...

Page 12: ...rface or seal will leak 4 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm torque 5 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 6 Slide...

Page 13: ...ged follow steps 1 through 7 under Removing Old Seal Page 11 check impeller for clogging follow steps 7 through 10 under Installing New Seal Page 12 for reassembly 7 Impeller and diffuser may be worn...

Page 14: ...14 1 1860 0795 5 6 11 12 13 16 17 18 19 15 14 10 10A 7 8 9 3 4 2 2A 20 22 23 24 21 P4E P4EA and P4E62 SERIES MAX E GLAS II POOL PUMP 3 4 through 3 HP Models...

Page 15: ...listed except as noted Key Nos 1 Motor 10 Impeller and 11 Diffuser are listed below Key Part Part No Description Qty No 1 Motor 1 Chart at Right 2 10 32x1 2 Screw 1 U30 692SS 2A Lock Washer 1 U43 22SS...

Page 16: ...8 Voltage Sticker 115 230 Volts U27 153 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63 12 Nameplate U33 174 P4R and P4RA SERIES DURA GLAS II POOL PUMP 1 through 2 1 2 H P Models Not illustrate...

Page 17: ...Pad 1 C104 78P 23 Motor Pad 1 C35 43 24 3 8 16 x 1 Hex Head Screw 4 U30 74SS Decal Suitable for outdoor use U27 635 Tag CAUTION 61002 0002 Tag CAUTION WARNING Bonding C63 12 Nameplate U33 174 P4R SER...

Page 18: ...U178 920P 20 Base Screw 2 U30 918SS 21 Base Washer 2 U43 41SS 22 Base w Motor Pad 1 C104 78P 23 Motor Pad 1 C35 43 24 3 8 16 x 1 Hex Head Screw 4 U30 74SS Decal Suitable for outdoor use U27 635 Tag C...

Page 19: ...consumer pur chaser Purchaser only Sta Rite shall have the option to re pair or replace the defective product at its sole discre tion Purchasers must pay all labor and shipping charges nec essary to...

Page 20: ......