STA-RITE DB10018T Owner'S Manual Download Page 12

Repair Parts

12

4

8A

 8B   

2

3

1

5A

5B

9

3465 0799 SR

6

Re

ad w

arn

ing

, in

str

uctio

ns, a

nd fe

atu

res

 in

 ow

ners

 m

anu

al

befo

re o

per

atio

n.  C

usto

me

r S

erv

ice

:  1

-8

00-

432

-4

021

Battery Operated Back -up System

M

icro

 P

ro

ces

so

r C

on

tro

lled 5

 S

ta

ge

 ba

tte

ry

 ch

ar

ge

r

12

 V

OL

T 2

.0

 AM

P

Charging

Charged

Fault

System Status

8

12

13

7

BA

TTER

Y CO

NNEC

TION

CHA

RG

ER

 CO

NNEC

TION

FLO

AT SW

ITCH C

ON

NE

CTIO

N

RE

PLA

CE

 FU

SE W

ITH

 S

AM

E 2

5 A

MP

 -

36V

 TYP

E AN

D RA

TING

 O

NLY

PU

MP FUSE

 &

CONN

EC

TIO

N

DISABLE  ENABLE

AUDIBLE ALARM

DISABLE W

HEN LIT

+

+

+

10

11

† Included in Fittings Package.

†† Includes 1-1/2 x 1-1/4 Reducer Bushings (2).

††† Included with Key No. 11.

• Not illustrated.

* Purchase locally.

# Included with Key No. 2.

Key No.

Part Description

DB10018T

DB20018T

1

Rubber Hose Coupling and Clamps

U74-68

U74-68

2

PVC Tee 1-1/2 x 1-1/2 Slip x 1-1/4 FNPTW/1-1/4 (†)(††)

U78-846P

U78-846P

3

Reducer Bushing

#

#

4

PVC Pipe Nipple, 1-1/4 NPT x Close (†)

U37-66P

U37-66P

5A

Coupling, 1-1/4 FNPT x 1-1/4 FNPT (†)

U212-261P

U212-261P

5B

Check Valve 

(†)

(†)

6

DC Backup Pump 

PS17-118

PS17-115

7

Replacement Fuse, - ATO 20 Amp, 12 Volt

*

*

8

Float Switch - 1/2HP, 8’, 16 Gauge

PS117-120P

PS117-120P

8A

Small Cable Ties (2)

*

*

8B

Large Cable Tie

*

*

9

Battery Case (Complete)

PS17-100

PS17-100

10

Two Face Tape, 1” x 2” (†)(2)

PS97-5

11

Charger Kit (DB10018T) (includes wires, junction box)

PS217-112

12

Charger Kit (DB20018T)

PS217-119

13

Battery Lead (†††)

PS117-114

Fittings Package

PS198-10

PS198-11

Summary of Contents for DB10018T

Page 1: ...AL AR M A C PO WER ON MIC RO PR OC ES SO R CO NT RO LLE D 5 STA GE BAT TER Y CH AR GE MA INT AIN ER 12 VOLT 8 AMP ALW AYS REA D WAR NING S IN INST RUC TION MAN UAL BEF ORE USIN G 3466 0799 SR DB10018T DB20018T 293 Wright Street Delavan WI 53115 2002 Sta Rite Industries Inc Printed in U S A S521 Rev 8 2 02 Installation Operation Parts For further operating installation or maintenance assistance Cal...

Page 2: ...3 Use this system only for backup sump pump duty in a residential application It is not designed as a pri mary sump pump 4 Do not lift pump by electrical cord Risk of electrical shock Do not lift the pump by the electrical cord lift pump only by the dis charge pipe lifting ring or handle on the pump Lifting by the cord can damage the cord 5 Pump clear water only with this pump 6 Pump is permanentl...

Page 3: ...a phase converter or if three leg ambient compensated extra quick trip overload relays of recommended size are not used our warranty is void Buyer s only remedy and Sta Rite Industries Inc s only duty is to repair or replace defective products at Sta Rite Industries Inc s choice Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty ser vice throug...

Page 4: ...must be pumped down as low as possible before going on to the next step To drain the sump pit follow either step 2A or 2B below 2A Raise the float on the float switch until the pump turns on Use a wooden broom handle or a stick to do this 2B If the sump pump has a piggy back type power cord remove the float switch power cord plug from the outlet and plug the pump power cord plug directly into the ...

Page 5: ... basin diameter at the bottom of the pit and the rec ommended depth of the sump basin is 18 Some additional materials you will need are 2 1 1 4 90 elbows and 2 1 1 4 close pipe nipples Figure 5 Remove the pre assembled check valve Battery Back up Pump comes preassembled with the check valve assembly installed on the discharge Remove this check valve assembly Elbow Back up Pump Discharge Tee Check ...

Page 6: ...gs into the tee first and then slip the cut off piece of discharge pipe into the bushing 12 Slip the tee and the back up pump subassembly onto the reducer bushing 13 Glue the cut off piece of pipe into the top of the reducer bushing in the top of the tee 14 Mount the float switch assembly Key No 8 loosely to the discharge pipe with the cable ties Key Nos 8A 8B See Figure 6 Approximately 2 5 63 5 m...

Page 7: ...lity 3 Make the third cut See Figure 8 TRIAL ASSEMBLY OF DOUBLE PUMP ASSEMBLY IN THE SUMP PIT 1 Connect the discharge pipe to the exterior discharge pipe with the rubber coupling and clamp kit Key No 1 Do not tighten the clamps until all the final adjustments are complete 2 Make the final adjustments Make sure the pumps and the switches do not interfere with each other Make sure there is plenty of...

Page 8: ...TION REPLACE FUSE WITH SAME 20 AMP 36V TYPE AND RATING ONLY PUMP FUSE CONNECTION DISABLE ENABLE AUDIBLE ALARM DISABLE WHEN LIT 20 Figure 9 Wiring Connections DB10018T Connect the To the Junction Box s Positive lead from the battery Positive battery connection Negative lead from the battery Negative battery connection Positive lead from the charger Positive charger connection Negative lead from the...

Page 9: ...ATUS ÉTAT DE FONCTIONNEMENT DE LA POMPE ESTADO DE FUNCIONAMIENTO DE LA BOMBA A C POWER STATUS 3464 0799 ÉTAT DU COURANT ALTERNATIF ESTADO DE LA CORRIENTE ALTERNA SILENCE ARRÉT SILENCIO ALARM ALARME ALARMA RESET RÉARMEMENT REPOSICIÓN Figure 12 DB20018T LED Panel Bicolor LED flashing Failed pre qualification test Yellow Green alternatively New battery may be needed Red Pump Run Battery voltage is gr...

Page 10: ...lls are being equalized This stage requires two hours to complete 4 Green LED light on indicates Float charge stage Battery is charged and ready for use Charging has stopped To maintain a full charge on the battery the yellow and green LED may alter nately turn back on This means the charger is briefly turning back on to keep the battery voltage from falling below a preset voltage level The 5 Stag...

Page 11: ...f a standard automobile battery with this charger is not recommended An automobile battery may require charging after only 1 2 hours of continuous use and the repeated charging cycles may cause early plate failure in the battery The maximum allowable size of a battery is 12 5 8 long 7 wide and 9 3 8 high 320 7mm x 177 8mm x 238mm including terminals so it will fit in the battery box BATTERY MAINTE...

Page 12: ...des 1 1 2 x 1 1 4 Reducer Bushings 2 Included with Key No 11 Not illustrated Purchase locally Included with Key No 2 Key No Part Description DB10018T DB20018T 1 Rubber Hose Coupling and Clamps U74 68 U74 68 2 PVC Tee 1 1 2 x 1 1 2 Slip x 1 1 4 FNPTW 1 1 4 U78 846P U78 846P 3 Reducer Bushing 4 PVC Pipe Nipple 1 1 4 NPT x Close U37 66P U37 66P 5A Coupling 1 1 4 FNPT x 1 1 4 FNPT U212 261P U212 261P ...

Reviews: