Carefully read and follow all safety instructions in this
manual or on pump.

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for
personal injury.

warns about hazards that 

will

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

can

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.
The word 

NOTICE

indicates special instructions which are

important but not related to hazards.

NOTICE:

Pump 

must 

be installed in a vertical position 

only.

Installing pump in any other position will void warranty.
1.

To avoid serious injury and/or property damage, read
these rules and instructions carefully. 

2.

Check your local codes before installing. You must 
comply with their rules.

3.

Vent sewage or septic tank according to local codes.

4.

Do not install pump in any location classified as
hazardous by National Electrical Code, ANSI/NFPA 
70-1984.

5.

Pump normally runs hot. To avoid burns when servicing
pump, allow it to cool for 20 minutes after shut-down
before handling it.

6.

Do not run pump dry. Dry running can overheat pump
and will void warranty. 

7.

Pump is permanently lubricated. No oiling or greasing is
required in normal operation. For overhaul, see
instructions under "Service".

Hazardous voltage. Can shock, burn, or

cause death. During operation the pump is in water. To
avoid fatal shocks, proceed as follows if pump needs 
servicing:

8A. Ground pump according to all applicable codes and ordi-

nances.

8B. Disconnect power to outlet box or circuit breakers before

servicing. 

8C. To reduce risk of electric shock, take care when changing

fuses or resetting circuit breakers. Do not stand in water
when working on control box or with circuit breakers.

Single Phase Pumps:

8D. When using cord and plug, plug into a grounded outlet with

it’s own individual branch circuit. When wiring to a system
control, connect pump ground lead to system ground.

Three Phase Pumps:

Risk of electrical shock. 

Do not remove cord

or strain relief. Do not connect conduit to pump.
8E. Three phase pumps are intended for permanent

connection only. Provide strain relief at control box for
power supply cord connection to box. All control compo-
nents must be UL listed and suitable for end use
application. Only qualified personnel should install and
service the pump and associated control equipment.

INSTALLATION

Risk of electrical shock. Can burn or kill.

Do not lift pump by power cord. See “Cord Lift Warning” on
Page 3.

NOTICE:  

Install pump on a hard, level surface (cement,

asphalt, etc.). Never place pump directly on earth, clay or
gravel surfaces. Basin must be at least 18" (458 mm) in 
diameter and  30" (762 mm) deep.

OWNER'S MANUAL

Installation • Operation • Repair Parts

Submersible, Effluent & Sewage/Solids Handling Pumps

700E/700EH, 700S and 900S Series, 

60 Hz, Single and Three Phase

Printed in U.S.A. © 2002

S325 

(Rev. 4/2/02)

SAFETY INSTRUCTIONS

Summary of Contents for 700E Series

Page 1: ...ns under Service Hazardous voltage Can shock burn or cause death During operation the pump is in water To avoid fatal shocks proceed as follows if pump needs servicing 8A Ground pump according to all...

Page 2: ...Power cord on 1 phase units is a 3 wire conductor with 3 prong ground ing type plug Do not modify cord or plug When using with plug in receptacle plug pump into a 3 wire ground ed grounding type rece...

Page 3: ...the terminals together with an amber handled screwdriver 5 Loosen cord nut and gently pull cord assembly out from motor cover Disconnect wires from cord set wires and connector are color coded for rea...

Page 4: ...passing it over shaft shoulder Seal faces must be clean and undamaged or seal may leak 4 Reassemble impeller washer and impeller nut 5 Install new capacitor See below for electrical connections to ca...

Page 5: ...Numbers ending in A REPAIR PARTS 700 SERIES REPAIR PARTS 700 SERIES Model H P Volts Phase Full Load Amps Capacitor Motor Ass y Volute Impeller Power Cord 700E PWE7E14 02 1 380 3 3 7 PW118 155 PW1 8E...

Page 6: ...Place O Ring in groove on seal plate mount motor on seal plate with socket head screws NOTICE It is good practice to replace O Ring each time pump is serviced 4 Turn assembly upside down and slide new...

Page 7: ...itor 1 Ph Only SeeChart Capacitor Cover PW3 16A Motor Cover PW3 32A Impeller See Chart Seal Plate O Ring U9 351 Capacitor Cover O Ring U9 339 Motor Assembly See Chart Seal Plate PW3 34 Shaft Seal U9 3...

Page 8: ...LUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE WARRANTY PERIOD PROVIDED HEREIN Certain states do not permit the ex...

Reviews: