Supplying power to the X-NUCLEO-LPM01A
40
7.3
Power source from an external DC power supply.
A jumper should be inserted in the 'EXT' position of JP3 as shown in
. An external DC power supply with an output voltage of 7 to 10 V with
500 mA minimum current capability is connected to connector CN7. Take care about the
positive and negative polarities of the CN7 connector pins, as shown in
.
Nevertheless, the X-NUCLEO-LPM01A has a series-connected reverse-polarity protection
diode to prevent damage in the event of an inadvertent reversed polarity connection (see
Figure 2: Hardware block diagram
Figure 7.
06Y9
džƚ
н
ϳͲϭϬsͬϱϬϬŵŵŝŶ
н
Ͳ
JP3 and CN7 (Ext Pwr setting)
Note:
The X-NUCLEO-LPM01A external voltage range has been limited to 10 V maximum to limit
self-heating of the board, and so limit measurement variations. Nevertheless, a standard
L7805 voltage regulator is used to convert the DC voltage from CN7 to 5 V. Thus the input