Debug support (DBG)
RM0453
1356/1454
RM0453 Rev 2
38.7
Cross trigger interface (CTI) and cross trigger matrix (CTM)
CTI and CTM taken together form the CoreSight embedded cross trigger (see
There are two CTI components, one dedicated to the CPU2 and one dedicated to the
CPU1. The CTIs are connected to each other via the CTM. The CTI registers are accessible
to the debugger via the corresponding access port and associated AHB.
Figure 387. Embedded cross trigger
The CTIs enable events from various sources to trigger debug activity. For example, a
breakpoint reached in one of the processor cores can stop the other processor.
Each CTI has up to eight trigger inputs and eight trigger outputs. Any input can be
connected to any output, on the same CTI or on another CTI via the CTM.
The trigger input and output signals for each CTI are listed in
.
Table 272. CPU2 CTI inputs
No.
Source signal
Source component
Comments
0
HALTED
CPU2
CPU2 halted - Indicates CPU2 is in debug mode.
1
-
-
Not used
2
-
-
Not used
3
-
-
Not used
4
-
-
Not used
5
-
-
Not used
6
-
-
Not used
7
-
-
Not used
MSv60369V2
AHB
Cortex
®
-M0+ CTI
Cortex
®
-M0+
CPU
HALTED
EDBGRQ
DBGRESTART
PPB
Cortex
®
-M4 CTI
Cortex
®
-M4
CPU
HALTED
EDBGRQ
CTM channels [3:0]
TRIGIN0
TRIGOUT0
TRIGOUT7
TRIGIN0
TRIGOUT0
DBGRESTART
TRIGOUT7