SM CODE
USB_SM_0
Error reporting
Refer to NVIC_SM_0
Fault detection time
Refer to NVIC_SM_0
Addressed fault model
Refer to NVIC_SM_0
Dependency on
Device
configuration
Refer to NVIC_SM_0
Initialization
Refer to NVIC_SM_0
Periodicity
Refer to NVIC_SM_0
Test for the diagnostic
Refer to NVIC_SM_0
Multiple-fault protection
Refer to NVIC_SM_0
Recommendations and known limitations
Refer to NVIC_SM_0
Table 146.
USB_SM_1
SM CODE
USB_SM_1
Description
Protocol error signals
Ownership
ST
Detailed implementation
USB communication module embeds protocol error checks (like overrun, underrun, NRZI, bit
stuffing etc.) conceived to detect network-related abnormal conditions. These mechanisms
are able anyway to detect a marginal percentage of hardware random failures affecting the
module itself
Error reporting
Error flag raise and optional interrupt event generation
Fault detection time
Depends on peripheral configuration (for example baud rate). Refer to functional
documentation
Addressed fault model
Permanent/transient
Dependency on
Device
configuration
None
Initialization
Depends on implementation
Periodicity
Continuous
Test for the diagnostic
Not applicable
Multiple-fault protection
USB_SM_2: Information redundancy techniques on messages
Recommendations and known limitations
Enabling related interrupt generation on the detection of errors is highly recommended.
Table 147.
USB_SM_2
SM CODE
USB_SM_2
Description
Information redundancy techniques on messages
Ownership
End user
or ST
Detailed implementation
The implementation of required information redundancy on messages, USB communication
module is fitted by hardware capability. It basically allows to activate the automatic insertion
(and check) of CRC checksums to packet data.
Error reporting
Error flag raise and optional interrupt event generation
Fault detection time
Depends on peripheral configuration (for example baud rate). Refer to functional
documentation.
Addressed fault model
Permanent/transient
Dependency on
Device
configuration
None
Initialization
Error reporting configuration, if interrupt events are planned
Periodicity
Continuous
UM2305
Hardware and software diagnostics
UM2305
-
Rev 10
page 81/110