9
Limitation
Issue observed
The OPAMP offset value is minimized using a trimming circuitry. At startup, the trimming values are initialized with
the preset factory trimming values. The trimming values of OPAMP1, OPAMP2 and OPAMP4 are not programmed
correctly, resulting in a large offset compared to the one specified.
Proposed workaround
The offset values of OPAMP1, OPAMP2 and OPAMP4 must be calibrated by software, applying the calibration
procedure described in the
STM32G4 Series advanced Arm
®
-based 32-bit MCUs
reference manual (RM0440), in
the
Calibration
section of the
Operational amplifiers (OPAMP)
chapter. Such a procedure is already implemented
in the STM32CubeG4 MCU Package.
Parts impacted
This applies only to the MB1367-based
boards within the following range of serial numbers:
A191300001-A191304602.