Connectivity line devices: reset and clock control (RCC)
RM0008
146/1096
Doc ID 13902 Rev 12
8.3.9
Backup domain control register (RCC_BDCR)
Address: 0x20
Reset value: 0x0000 0000, reset by Backup domain Reset.
Access: 0
≤
wait state
≤
3, word, half-word and byte access
Wait states are inserted in the case of successive accesses to this register.
Note:
LSEON, LSEBYP, RTCSEL and RTCEN bits of the
Backup domain control register
are in the Backup domain. As a result, after Reset, these bits are write-
protected and the DBP bit in the
Power control register (PWR_CR)
has to be set before
these can be modified. Refer to
for further information. These bits are
only reset after a Backup domain Reset (see
Section 8.1.3: Backup domain reset
). Any
internal or external Reset will not have any effect on these bits.
Bit 3
TIM5EN
: Timer 5 clock enable
Set and cleared by software.
0: Timer 5 clock disabled
1: Timer 5 clock enabled
Bit 2
TIM4EN
: Timer 4 clock enable
Set and cleared by software.
0: Timer 4 clock disabled
1: Timer 4 clock enabled
Bit 1
TIM3EN
: Timer 3 clock enable
Set and cleared by software.
0: Timer 3 clock disabled
1: Timer 3 clock enabled
Bit 0
TIM2EN
: Timer 2 clock enable
Set and cleared by software.
0: Timer 2 clock disabled
1: Timer 2 clock enabled
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Reserved
BDRST
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RTC
EN
Reserved
RTCSEL[1:0]
Reserved
LSE
BYP
LSE
RDY
LSEON
rw
rw
rw
rw
r
rw
Bits 31:17 Reserved, always read as 0.
Bit 16
BDRST
: Backup domain software reset
Set and cleared by software.
0: Reset not activated
1: Resets the entire Backup domain