Pulse width modulation module
This type of comparison allows a flexible control of the PWM signal. For the register
locations refer to the
PWM control register PWMCON0
Register PWMCON0 controls the function of the timers of the four PWM channels and the
channel specific interrupts. Having the control bit organized in functional groups allows to
start or to stop all the four PWM timers simultaneously with one bit-field instruction.
PWMCON0 (FF30h / 98h)
SFR
Reset Value: 0000h
PWM control register PWMCON1
Register PWMCON1 controls the operating modes and the outputs of the four PWM
channels. The basic operating mode for each channel (standard = edge aligned, or
symmetrical = center aligned PWM mode) is selected by the mode bit PMx. Burst mode
(channels 0 and 1) and single shot mode (channel 2 or 3) are selected by separate control
Table 53. PWM module channel specific register addresses
Register
Address
Reg. space
Register
Address
Reg. space
PW0
FE30h / 18h
SFR
PT0
F030h / 18h
ESFR
PW1
FE32h / 19h
SFR
PT1
F032h / 19h
ESFR
PW2
FE34h / 1Ah
SFR
PT2
F034h / 1Ah
ESFR
PW3
FE36h / 1Bh
SFR
PT3
F036h / 1Bh
ESFR
These registers are not bit-addressable.
PP0
F038h / 1Ch
ESFR
PP1
F03Ah / 1Dh
ESFR
PP2
F03Ch / 1Eh
ESFR
PP3
F03Eh / 1Fh
ESFR
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PIR3 PIR2 PIR1 PIR0
PIE3 PIE2 PIE1 PIE0 PTI3 PTI2 PTI1 PTI0
PTR3 PTR2
PTR1 PTR0
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
Bit
Function
PTRx
PWM Timer x Run Control bit
‘0’: Timer PTx is disconnected from its input clock
‘1’: Timer PTx is running
PTIx
PWM Timer x Input Clock Selection
‘0’: Timer PTx clocked with CLK
CPU
‘1’: Timer PTx clocked with CLK
CPU
/ 64
PIEx
PWM Channel x Interrupt Enable Flag
‘0’: Interrupt from channel x disabled
‘1’: Interrupt from channel x enabled
PIRx
PWM Channel x Interrupt Request Flag
‘0’: No interrupt request from channel x
‘1’: Channel x interrupt pending (must be reset via software)