9.1.14 ADC_OUT
The ADC_OUT register contains the result of the analog-to-digital conversion of the ADCIN
pin voltage.
Any attempt to write to the register causes the command to be ignored and the
NOTPERF_CMD flag to rise (see
).
9.1.15 OCD_TH
The OCD_TH register contains the overcurrent threshold value (see
for details).
The available range is from 375 mA to 6 A, steps of 375 mA, as shown in
.
Table 20.
ADC_OUT value and torque regulation feature
VADCIN/ VREG
ADC_OUT [4..0]
Reference voltage
0
0 0 0 0 0
31.25
mV
1/32
0 0 0 0 1
62.5
mV
…
…
…
…
…
…
…
30/32
1 1 1 1 0
968.8
mV
31/32
1 1 1 1 1
1
V
Table 21.
Overcurrent detection threshold
OCD_TH [4..0]
Overcurrent detection threshold
0
0 0 0
0
31.25
mV
0
0 0 0
1
62.5
mV
…
…
…
…
…
…
1
1 1 1
0
968.8
mV
1
1 1 1
1
1