Functional description
L6482
20/73
Doc ID 023768 Rev 1
Figure 4.
Charge pump circuitry
6.4 Microstepping
The driver is able to divide the single step into up to 16 microsteps. Stepping mode can be
programmed by the STEP_SEL parameter in the STEP_MODE register (
Step mode can only be changed when bridges are disabled. Every time the step mode is
changed, the electrical position (i.e. the point of microstepping sinewave that is generated)
is reset to the first microstep and the absolute position counter value (
) becomes
meaningless.
Figure 5.
Normal mode and microstepping (16 microsteps)