background image

IMPORTANT NOTICE – PLEASE READ CAREFULLY

STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST
products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders. ST
products are sold pursuant to ST’s terms and conditions of sale in place at the time of order acknowledgement.

Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of
Purchasers’ products.

No license, express or implied, to any intellectual property right is granted by ST herein.

Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.

ST and the ST logo are trademarks of ST. For additional information about ST trademarks, please refer to 

www.st.com/trademarks

. All other product or service

names are the property of their respective owners.

Information in this document supersedes and replaces information previously supplied in any prior versions of this document.

© 2019 STMicroelectronics – All rights reserved

UM2654

UM2654

 - 

Rev 1

page 10/10

Summary of Contents for EVAL-L99MOD5xXP

Page 1: ...s including a standby mode These evaluation boards are designed to drive multiple brushed DC motors and additional loads in high side configuration such as bulbs LEDs or protected supply The STSW L99M...

Page 2: ...1 Evaluation kit connection The following figure shows how to connect the evaluation kit Figure 1 Evaluation kit connection UM2654 Evaluation kit connection UM2654 Rev 1 page 2 10...

Page 3: ...stall the FTDI driver from the supplier s website 3 Complete the connection as Figure 1 Evaluation kit connection shows then power on the kit 4 Run the L99MOD5x exe and select the appropriate device f...

Page 4: ...the checksum is correct OK is displayed otherwise the indicator turns red and ERROR is displayed 4 Continue Diagnose if this option is checked the GUI reads the status register continuously 5 Read and...

Page 5: ...nfiguration registers settings 4 Diagnostic Status if any of these states occur the corresponding status display will become red Once the control register changes the status register and all diagnosti...

Page 6: ...play window 2 Current value 3 Current detection select output 4 Current monitor start button 5 Clear window value button 6 PWM configuration on off frequency and duty cycle settings UM2654 Description...

Page 7: ...is possible to write directly in the register by clicking on the desired bit as shown in Figure 6 Control registers overview tab Figure 7 Status registers overview tab UM2654 Description of the graph...

Page 8: ...obal Status Regster this is device dependant 3 SPI History the SPI commands sent to the device are recorded here 4 Clear History it clears the SPI history 5 Continue Diagnose if this option is checked...

Page 9: ...Revision history Table 1 Document revision history Date Version Changes 20 Nov 2019 1 First release UM2654 UM2654 Rev 1 page 9 10...

Page 10: ...ts and ST assumes no liability for application assistance or the design of Purchasers products No license express or implied to any intellectual property right is granted by ST herein Resale of ST pro...

Reviews: