Obsolete Product(s) - Obsolete Product(s)
5/15
UM0073 - USER MANUAL
READER FIRMWARE UPGRADE
The FEIG MR100 reader firmware needs, first, to be upgraded, for it to work with LRI64 contactless mem-
ory devices. To download the “ABDG30100-mr100-a.mhx” firmware code into the MR100 reader flash
memory, follow the steps described in the “N10301-0e-ID-A.pdf” guide. When this new firmware is correct-
ly installed, follow the actions listed, below, to install all the new software tools:
1.
Remove all existing FEIG tools (IC_START, STM demokit, ...) from the computer.
2.
Install the “Feig IC_START 6.0” software which supports the LRI512 and LRI64 tags in Inventory Read
and Write
3.
Launch the IC_Start software. Go to the configuration mode, and set the ISO15693 protocol to:
–
10% ASK modulation
–
1/4 transmission data coding
–
ASK demodulation
–
Fast data rate on reception
This is illustrated in
. Store this setting by pressing the save button.
Install the STM demokit software that is found in the “DemoKitLR_V30.zip” file.
Figure 3. FEIG IC_Start Software in Configuration Mode