![ST ARMIC30 User Manual Download Page 3](http://html1.mh-extra.com/html/st/armic30/armic30_user-manual_1355875003.webp)
UM0193
Hardware
1 Hardware
The ARMIC30 Evaluation Board is designed to evaluate and develop Industrial Controller
(IC) applications that use several different communication interfaces as shown in
Figure 1.
ARMIC30 Communication interfaces
The ARMIC30 comes on a double-face printed circuit board with only two copper layers.
Circuit routing is Class 5 accuracy meaning that the smallest route/isolation distance is 8 mil
(0.2032 mm) and the smallest hole diameter is 20 mil (0.5080 mm). Board dimensions are
132 x 116 mm.
Figure 2.
ARMIC30 board presentation
Ai11696
STR730F
MCU
RS-232
ST202E
RS-485
ST485A
CAN
L9616
SPI
I²C
JTAG
UART0
UART1
CAN0
JTAG
I2C0
BSPI0
8-MHz
Crystal
MCU Reset
RS-485
Connection
CAN
Connection
I²C
Connection
Standard
Power Supply
Connection
Power Supply
Industrial Bus
RS-232
Connection
SPI
Connection
Input GP
Connection
Output GP
Connection
GP PowerSpin
Connections
JTAG
Connection
STR730
MCU
User
LEDs