6
Installation
Safety Precautions
Before starting the installation, consideration should be given to
how the installation is to be carried out, ensuring
Adequate space and clearances above, below and on all sides of
the cooktop.
Availability of earthed power.
The mechanical strength of supporting cabinetry.
Adequate ventilation and clearance to nearby surfaces are provided.
The installation work must be undertaken by a qualifi ed and competent person in conformity with all
current building and electrical standards, as well as all local regulations in force. The manufacturer
does not accept any liability for any damage or injury caused by improper installation.
Before connecting to the mains supply ensure that the mains power corresponds with the
requirements on the cooktop’s rating plate.
For cooktops featuring an earth wire, make sure the electric plant of the building is correctly earthed.
•
•
•
•
Create Cutout In The Benchtop
Note the dimensions of the cutout. Ensure the following:
that all required clearances are observed.
that there is adequate ventilation for the fan to operate.
These are shown below.
1.
2.
width
490mm
model
width
2 zone Domino
268 mm
3 zone 60 cm
560 mm
4 zone 60 cm
560 mm
4 zone 80 cm
750 mm
55 mm
600 mm
150 mm
600 mm
minimum
clearances shown