Remote Maintenance Gateway 

RMG/938

with eSOM/7210 

First Steps 

SSV Software Systems GmbH 

Dünenweg 5 
D-30419 Hannover 
Phone:  +49 (0)511/40 000-0 
Fax: 

+49 (0)511/40 000-40 

Email:  [email protected] 

Document Revision: 1.0 

Date: 2022-06-03 

 
 

Summary of Contents for RMG/938

Page 1: ...ance Gateway RMG 938 with eSOM 7210 First Steps SSV Software Systems GmbH D nenweg 5 D 30419 Hannover Phone 49 0 511 40 000 0 Fax 49 0 511 40 000 40 Email sales ssv embedded de Document Revision 1 0 D...

Page 2: ...2 and COM3 7 4 3 Power Supply 8 5 OPERATION 9 5 1 Booting the RMG 938 9 5 2 Accessing the SSV WebUI 9 5 3 Accessing the SSV WebUI with DHCP enabled 10 5 4 LAN1 Configuration 12 5 5 Access via Telnet 1...

Page 3: ...iew about the initial operation and the first steps of use with the RMG 938 IMPORTANT You will need further equipment to operate the RMG 938 Please refer to chapter 3 1 1 Conventions Convention Usage...

Page 4: ...be at least 2 5 W Please pay attention that the power cord or other cables are not squeezed or damaged in any way when you set up the device Do NOT turn on the power supply while connecting any cables...

Page 5: ...ired 24 VDC power supply One Ethernet cross over cable or two Ethernet patch cables and a switch To configure the RMG 938 a computer with the following features is required Windows 7 or higher Web bro...

Page 6: ...et patch cables over a hub or switch like shown in fig 2 Figure 1 Ethernet link with cross over cable Please note For the Ethernet connection in fig 1 it is required to use a cross over cable Do not u...

Page 7: ...al Port RX TX B4 Signal Ground Table 2 Screw terminals COM2 Terminal Signal B2 COM3 Serial Port TXD RS232 RX TX RS485 B3 COM3 Serial Port RXD RS232 RX TX RS485 B4 Signal Ground Table 3 Screw terminals...

Page 8: ...own in fig 4 Figure 4 Power supply for the RMG 938 Terminal Signal A3 Vin 11 28 VDC A4 GNDin Table 4 Screw terminal power CAUTION Providing the RMG 938 with a higher voltage than the regular 11 28 VDC...

Page 9: ...may take up to one minute 5 2 Accessing the SSV WebUI To open the login page of the SSV WebUI enter the ex factory IP address and port number of LAN1 of the RMG 938 manually in a web browser https 19...

Page 10: ...e open in Windows Control Panel Network and Internet View network com puters and devices The RMG 938 should show up in this list Figure 6 Selecting the RMG 938 Just right click on the RMG 938 to open...

Page 11: ...te Maintenance Gateway RMG 938 First Steps Document Revision 1 0 11 Figure 7 The properties dialog shows the current IP address Now you are able to access the RMG 938 via a Telnet client or a web brow...

Page 12: ...Network LAN1 Figure 8 LAN1 settings To enable the automatic IP address assignment via DHCP follow these steps 1 In the section IP address configuration enable the radio button automatically 2 Click o...

Page 13: ...from the menu Services General enable the checkbox in the line Telnet server and click on Apply To access the RMG 938 via Telnet open a Telnet client program like TeraTerm on your host PC and enter t...

Page 14: ...on Apply The RMG 938 comes with a pre installed FTP server which allows the file transfer via Ethernet between a PC and the RMG 938 To access the RMG 938 via FTP use an FTP client like e g FileZilla...

Page 15: ...ion To configure the Bluetooth settings choose from the menu Network Bluetooth Figure 11 Bluetooth settings To enable the Bluetooth interface follow these steps 1 In the section General configuration...

Page 16: ...w these steps 1 In the section General configuration enable the checkbox 2 Click on Apply A green arrow on the right side indicates that Node RED is enabled After a few seconds the Node RED editor can...

Page 17: ...ance Gateway RMG 938 First Steps Document Revision 1 0 17 The Node RED editor offers a simple flow to display incoming Bluetooth data in the debug window on the right side of the workspace Figure 13 N...

Page 18: ...Port RS485 RX TX A2 COM2 Serial Port RS485 RX TX A3 Vin 11 28 VDC A4 Power Ground B1 B2 COM3 Serial Port TXD RS232 RX TX RS485 B3 COM3 Serial Port RXD RS232 RX TX RS485 B4 Signal Ground Table 5 Pinout...

Page 19: ...Ready S2 VPN state Off Connecting Ready Table 1 LED functions The LED S2 shows the VPN connection state by different flashing The following table de scribes the functions of the particular LED signal...

Page 20: ...any ssv software systems DOCUMENT HISTORY Revision Date Remarks Name Review 1 0 2022 06 03 First version WBU ENE The content of this document can change any time without announcement There is taken ov...