③
Connecting the cables
To connect the cables, remove the terminal box cover and use the insulated
crimping terminals on the terminal block.
Connect by crimping the + input terminal to the + terminal (red) and the - input
terminal to the - terminal (blue). (See Figure 3-1)
* To remove the cover, undo the locking screws (hex set screws)
Figure 3-1
④
Locking
After partially attaching the terminal box cover, lock the cover in place using the
locking screw.
⑤
Other details
All other aspects of the installation should be carried out in compliance with the
“New Guidelines for Industrial Electrical Equipment Explosion-Proofing 1979”
issued by the Industrial Safety Institute of the Ministry of Labor and in
accordance with “technical procedures that comply with international standards”.