SSS Siedle MOCT 711-0 Product Information Download Page 8

4

Application

The colour Touchscreen Monitor
MOCT 711-... with backlit 10 cm
(4“) colour LCD and touchpanel is
designed as a surface-mounted wall
unit. It can also be mounted in com-
bination with an intercom system, or
in a flush or table-top mounted ver-
sion.  The MOCT 711-... features an
integrated video memory which
automatically stores 32 colour video
images with date and time. 
The touchscreen can be configured
using a laptop to form a switchbo-
ard for the In-Home bus and/or the
EIB system. 
This control centre is then used to
transmit control commands, start
interrogation routines and receive
messages.  

The Touchscreen Monitor 711-...
is not suitable for continuous
operation!

Surface mounting instructions

A separate flush-mounted junction
box should be installed under each
monitor to provide supply line clea-
rance. The most favourable viewing
angle is achieved by mounting the
touchpanel at eye level. The lighting
conditions should also be taken into
account. The incidence of light
directly on the touchpanel will redu-
ce the contrast. 

Wall mounting

The MOCT 711-... can be surface-
mounted on the wall without the
need for system-linked accessories.

Open the unit

(no illustration) 

Detach the plug-in connections bet-
ween the top and bottom part of
the housing at the terminal PCB. 

Fasten the unit on the wall

(no illustration)

Connect in accordance with the
relevant circuit diagram.

Mounting the combination 

BTS/BTC 750-... MOCT 711-...

5

Open the unit.

(no illustration) 

Detach the plug-in connections bet-
ween the upper and lower part of

the housing at the terminal PCB.

7

Break off the prepared connecting

web „a“ in the lower parts of the
housings and screw the two lower
housings together using the 2 con-
necting elements enclosed with the
monitor. 

Fasten the units on the wall.

Connect in accordance with the
relevant circuit diagram. 

9

Connect the  BTS/BTC 750-...

MOCT 711-... to the video 2-wire
bus. 

The VBE 650-... must be supplied
via a separate VNG 602-...

At the VBE 650-... , slide switch S2
and S4 must be set to the ON posi-
tion. 

Circuit diagram information

w

Plug in and connect the connec-

ting cable for the monitor and
BTS/BTC 750-... which is enclosed
with the VBE 650-... . Please obser-
ve the product information.

10

Connect the BTS/BTC 750-...

MOCT 711-... to the Siedle In-Home
Bus. 

The BVE 650-... must be supplied
via a separate VNG 602-...

Circuit diagram information

w

Plug in and connect the connec-

ting cable for the monitor and
BTS/BTC 750-... which is enclosed
with the BVE 650-... . Please obser-
ve the product information.

y

In order to loop through from one

BVVU 650-... to other BVVU units,
first remove the terminating element
at “TaD” and “TbD”.

11 

Connect the BTS/BTC 750-...

MOCT 711-... with coaxial cable.

12 

Comparison MO 611-.../

MOM/MOC 611-.../ MOM/MOC/
MOCT 711-... .

13 

Replace the plug-in connections

between the upper and lower part
of the housing on the terminal PCB
of the MOCT 711-..., push the insu-
lating sleeve over the coaxial con-
nector and close the housing ele-
ments. 

14

User interface of the 

MOCT 711-... 

a

Touchscreen panel

b

Buttons for picture colour 

contrast control 

Buttons for picture brightness 

control 

d

Switching on the monitor

Press the Play button

once

:

- Display stored images (the latest
image is displayed first)
Press the Play button 

twice

:

- Direct image mode, only possible
with permanently active video signal
Requirement: e.g. camera continu-
ously operational, DIL switch 1
(MSS) on OFF. 
The system must also support these
functions (e.g. coaxial video).

e

Reset - Switching off the monitor 

f

Control buttons for camera 

control

g

BCD switch to set the timer. Only 

adjustable with the upper part of

the housing removed. 

h

System connecting terminals 

Ta, Tb

i

Socket for the adapter cable to 

the laptop

15

DIL switch S2 

1 = MSS - Direct image mode;
Switch on with “Play" button
2 = Continuous operation

Settings:

0  secs. (timer off) 

1

= 10 

secs. 

2

= 20 secs. 

3

= 30 secs. 

4

=

40 secs. 

5

=

50 secs. 

6

=

60 secs.

7

= 90 

secs. 

8 = 120 secs. 

9 = 180 secs.

Status on delivery

0 =  0 secs. 

Specifications MOCT 711-0

• Screen 78 x 53 mm, landscape
format
• Colour system PAL 
• Pixel 230.400 

English

Montage

Summary of Contents for MOCT 711-0

Page 1: ...our Monitor MOCT 711 0 Moniteur couleur à écran tactile MOCT 711 0 Monitor a colori a schermo tattile MOCT 711 0 Touchscreen kleuren monitor MOCT 711 0 Touchscreen farvemonitor MOCT 711 0 Touchscreen färgbildskärm MOCT 711 0 Touchscreen dotykový barevný monitor MOCT 711 0 ...

Page 2: ...1 5 7 3 8 ...

Page 3: ...9 10 ...

Page 4: ...12 11 ...

Page 5: ...13 14 15 15 ...

Page 6: ...den Am VBE 650 muss Schiebe schalter S2 und S4 auf ON gestellt werden Schaltplanhinweis w Die dem VBE 650 beiliegenden Verbindungskabel für Monitor und BTS BTC 750 stecken und an schließen Bitte Produktinformation beachten 10 Anschluss des BTS BTC 750 MOCT 711 mit Siedle In Home Bus Der BVE 650 muss über ein separates VNG 602 versorgt werden Schaltplanhinweis w Die dem BVE 650 beiliegenden Verbind...

Page 7: ...ls betätigt erfolgt keine erneute Abspeicherung Falls die Speicherkapazität erschöpft ist wird das älteste gespeicherte Bild gelöscht damit das neue Bild gespeichert werden kann Der MOCT schaltet sich ca 15 Sek nach Gesprächsende ab Falls der Türruf nicht angenommen wird er folgt die Abschaltung nach 45 Sek Mit der Taste Reset kann der MOCT sofort abgeschaltet werden Gespeicherte Bilder anzeigen u...

Page 8: ...0 must be supplied via a separate VNG 602 At the VBE 650 slide switch S2 and S4 must be set to the ON posi tion Circuit diagram information w Plug in and connect the connec ting cable for the monitor and BTS BTC 750 which is enclosed with the VBE 650 Please obser ve the product information 10 Connect the BTS BTC 750 MOCT 711 to the Siedle In Home Bus The BVE 650 must be supplied via a separate VNG...

Page 9: ...ound 30 seconds have expired no repeat storage process takes place If the storage capacity is exhausted the oldest stored image is deleted to allow the latest picture to be stored The MOCT switches off around 15 secconds after the end of a call If the door call is not accepted the system switches off after 45 secs The MOCT can be switched off immediately using the Reset button Displaying and delet...

Page 10: ...érieur correspondant 9 Branchement du BTS BTC 750 MOCT 711 avec bus vidéo 2 fils Le VBE 650 doit être alimenté par un VNG 602 séparé Les commutateurs à coulisse S1 et S2 du VBE 650 doivent se trouver sur ON Note de branchement w Branchez le moniteur et le BTS BTC 750 avec les câbles de liaison joints au VBE 650 Veuillez lire l information produit correspondan te 10 Branchement du BTS BTC 750 MOCT ...

Page 11: ...t Une mémorisation manuelle de l image n est pas possible Si la touche d appel est de nouveau activée en l espace de 30 s après l appel précédent il n y a pas de nouvelle mémorisation Si la capaci té de mémorisation est épuisée l i mage la plus ancienne sera effacée pour permettre de mémoriser la nouvelle image Le MOCT s éteint env 15 s après la communication interphonique Si l appel n est pas acc...

Page 12: ...gamento esterno 9 Collegamento del BTS BTC 750 MOCT 711 con bus video bifilare Il VBE 650 deve essere alimenta to tramite un VNG 602 separato Sul VBE 650 è necessario impo stare gli interruttori a scorrimento S2 e S4 su ON Indicazioni sullo schema elettrico w Inserire e collegare i cavi d allacci amento acclusi al VBE 650 per il monitor ed il citofono BTS BTC 750 Osservare l informazione prodotto ...

Page 13: ...tazione Una memorizzazione manuale dell immagine video non è possi bile Se il tasto di chiamata viene nuova mente azionata prima che passino all incirca 30 sec non avviene alcuna ulteriore memorizzazione Se la capacità di memoria è esaurita la più vecchia immagine salvata viene cancellata per far sì che possa essere salvata la nuova immagine All incirca 15 sec dopo il termine della chiamata il MOC...

Page 14: ...Aansluiting van de BTS BTC 750 MOCT 711 met video 2 draads bus De VBE 650 moet via een apar te VNG 602 gevoed worden Op de VBE 650 moet de schuif schakelaar S2 en S4 op ON gezet worden Schakelschema instructie w Steek de verbindingskabels voor de monitor en de BTS BTC 750 in die met de VBE 650 zijn meegele verd en sluit ze aan Kijk a u b in de productinformatie 10 De BTS BTC 750 MOCT 711 met de Si...

Page 15: ...erabeeld is niet mogelijk Indien de oproeptoets binnen ca 30 sec nogmaals ingedrukt wordt wordt het beeld niet opnieuw opgeslagen In de geheugencapaciteit op is wordt het oudste opgeslagen beeld gewist zodat er een nieuw beeld opgeslagen kan worden De MOCT schakelt zichzelf ca 15 sec na afloop van het gesprek uit Indien de deuroproep niet wordt aangenomen vindt het uitschakelen na 45 sec plaats Me...

Page 16: ...n separat VNG 602 På modulet VBE 650 skal skyde kontakterne S2 og S4 stilles på ON Vejledning til ledningsdiagram w Slut forbindelseskablerne der leveres sammen med VBE 650 til monitoren og BTS BTC 750 Vær opmærksom på den medføl gende produktinformation 10 Tilslutning af BTS BTC 750 MOCT 711 med Siedle In Home Bus BVE 650 skal forsynes via en separat VNG 602 Vejledning til ledningsdiagram w Slut ...

Page 17: ...kalds trykket betjenes igen inden for 30 sekunder sker der ingen fornyet lagring Hvis billedlageret er fyldt slettes det ældste lagrede billede for at tillade lagring af det nye billede MOCT frakobles automatisk ca 15 sekunder efter samtalens afslutning Hvis døropkaldet ikke besvares sker frakobling efter 45 sekunder Med trykknappen Reset er det muligt at frakoble MOCT øjeblikkeligt Visning og sle...

Page 18: ...omkop plarna S2 och S4 ställas in i läge ON Anvisningar för kopplingsschema w Anslut förbindningskabeln som medföljer VBE 650 för monitor och BTS BTC 750 Beakta produktinformationen 10 Anslutning av BTS BTC 750 MOCT 711 med Siedle In Home buss BVE 650 måste försörjas via en separat VNG 602 Anvisningar för kopplingsschema w Anslut förbindningskabeln som medföljer VBE 650 för monitor oc BTS BTC 750 ...

Page 19: ...ycks in igen inom 30 sekunder sker ingen ny bildlagring När minnet blir fullt raderas den äld sta lagrade bilden så att den nya bil den kan lagras MOCT stänger av sig efter ca 15 sekunder efter samtalets slut Om dörranropet inte tas emot sker bort koppling efter 45 sekunder Med knappen Reset kan MOCT ome delbart stängas av Visa och radera lagrade bilder Vid intryckning av knappen Play visas de lag...

Page 20: ...MOCT 711 s 2drátovou sběrnicí videa VBE 650 musí být zásobován separátním VNG 602 Na VBE 650 musí být posuvný spínač S2 a S4 nastaven na ON Pokyny ke schématu zapojení w K VBE 650 přiložené spojovací kabely pro monitor a BTS BTC 750 nastrčit a připojit Prosím dodržujte informaci o výrobku 10 Připojení BTS BTC 750 MOCT 711 se In Home sběrnicí Siedle BVE 650 musí být zásobován separátním VNG 602 Pok...

Page 21: ...azu kamery do paměti není možné Jestliže je volací tlačítko před uply nutím cca 30 sekund opět stisknu to nedojde k opětovnému uložení obrazu do paměti Když je kapacita paměti vyčerpána je nejstarší obraz vymazán aby mohl být nový obraz uložen do paměti MOCT se po cca 15 s po ukončení hovoru vypne Pokud nebylo volání ode dveří přijato proběhne vypnutí po 45 sekundách Tlačítkem Reset může být MOCT ...

Page 22: ...many Best Nr 0 1101 132037 S Siedle Söhne Telefon und Telegrafenwerke Stiftung Co OHG Postfach 1155 D 78113 Furtwangen Bregstraße 1 D 78120 Furtwangen Telefon 49 0 7723 63 0 Telefax 49 0 7723 63 300 www siedle de info siedle de ...