SSS Siedle AGW 671-0 Product Information Download Page 3

3

English

Network configuration (Customer)

Co

mmissioning date

:

IP

 address

:

Subnet mask

:

Default gateway

:

DHCP server activated?

IP pool, start

:

IP

 pool, end

:

Serial number

:

MAC address

:

Location

:

Application

Access Gateway for the physical sep-
aration of 2 networks at an Access 
server. To operate Access end devices 
in different networks, two or more 
proprietary networks can be con-
nected to an Access system and still 
be kept strictly separate from each 
other by using one or more gate-
ways in larger network structures.
Operation of the AGW 671-… 
requires the Access server V. 6.0.1 
as a minimum requirement. If appli-
cable, a software upgrade/update 
must be carried out.
Up to 25 Access end devices as well 
as call groups with up to 10 Access 
end devices can be operated in 
the customer network through the 
Access Gateway. Solutions requiring 
a higher number of Access end 
devices in the customer network are 
possible and can be requested from 
the Access Service Centre.

General information

Commissioning of the 
Access Gateway is described in the 
Access Professional commissioning 
instructions and is available in the 
Siedle download area.

Electrical voltage

Mounting, installation and servicing 
work on electrical devices may only 
be performed by a suitably qualified 
electrician.

Scope of supply

• AGW 671-…
• Power supply unit
• this product information

Mounting

• Connection to the Access network 
takes place via the LAN socket 
”Access”. The IP address is issued by 
DHCP. No other settings are required 
here.
• Connection to the customer 
network takes place via the LAN 
socket ”Customer”. The IP address 
is pre-set.

Specifications

Components:
CPU: AMD Geode LX800; 500 MHz
Working memory: 
256 MB DDR SDRAM
LAN: 3 x 100 Mbit/s
Operating voltage: 12 V DC
Typical current consumption: 
max. 24 W
Ambient temperature: 
0 °C to +50 °C

D

imensions (mm) W x H x D: 

200 x 200 x 52

Commissioning

• The IP address of the Access server 
is required for the complete commis-
sioning of the Access Gateway.
• The laptop and Access Gateway 
must be in the same network. 
When accessing via the LAN socket 
”Customer”, adjust the network 
address of the laptop to the IP 
address range (192.168.240.x).

Pr

ocedure

Connect the laptop to the 

LAN socket ”Customer” of the 
Access Gateway.

Open a browser and enter the IP 

address ”192.168.240.1”.

The login window will open up.

Enter password ”admin”.

Configure the Access Gateway.