Air Filter Replacement

The air filter is located on the non-hose end of the portable 
Jet-Kleen Limited unit . The filter is accessed by removing the 
filter guard, which is secured with four screws .  Simply pull 

out the used filter and insert a new one (Figure 3) .
Replacing the filter is recommended at least every six 
months, although your specific application and operating 
conditions may warrant much more frequent filter replace-
ment .
Replacement filters for the entire Jet-Kleen series are avail-
able from Specialized Safety Products .

IMPORTANT

: To prevent overheating and possible perma-

nent damage to the unit, DO NOT run the Jet-Kleen Limited 
continuously for more than three hours .

T

eChniCal

 i

nformaTion

CATALOG

NUMBER

HOSE

ELECTRICAL  

SPECIFICATIONS

WEIGHT

JKL-115

96

"

 (244cm)

115V, 1Ph, 50/60Hz

18.6 lbs. (8.4kg)

JKL-240

96

"

 (244cm)

240V, 1Ph,  50/60Hz

18.6 lbs. (8.4kg)

MODELS AND SPECIFICATIONS

Output pressure greater than 3 PSI is legally 
prohibited in Europe. In the US, we conform to 
OSHA Standard number 1910.242(B).

GOVERNMENT REGULATIONS

The Jet-Kleen Limited has been designed in accordance 

with the following directives:

EN55014-1 

EMC Directive (Emissions)

EN55014-2 

EMC Directive (Immunity)

EN60335-2-69 

Low Voltage (Electrical Safety Testing)

EN61000-3-2 

EMC - Limits for harmonic current emissions

EN61000-3-3 

EMC - Limits of voltage changes, fluctua-
tions and flicker in public low-voltage 
supply systems

PSI SPECIFICATIONS

1 .9 PSI  

             

VELOCITY

22,000' per minute

NOISE LEVEL

Below 78dB (A)

SPACE REQUIREMENTS

•  Weight: 18 .6 lbs . 

(8 .4kg)

•  Dimensions: 

16 .6"L x 11 .3"W x 13 .7"H (42 .2cm 

x 28 .7cm x 

34 .8cm)

SHIPPING REQUIREMENTS

•  Weight: 23 lbs . (8 .4kg)
•  Dimensions: 23"L x 16"W x 17"H (58 .4cm x 40 .6cm x 

43 .2cm)

Figure 3.  Changing the air filter.

SPECIALIZED 

SAFETY

 PRODUCTS

 

A Division of The A.W.T. World Trade Group

4321 N. Knox Ave., Chicago, IL 60641 USA 

773.777.7100 • Fax:773.777.0909

[email protected] 

www.specializedsafetyproducts.com

J

et

-K

leen

tm

 

6

 

Installation & Operation Manual

p

S

S

A Product of

Summary of Contents for Jet-Kleen JKL-115

Page 1: ...Safe Personnel Blow Off Drying System Installation Operation Manual MODELS JKL 115 JKL 240...

Page 2: ...Installation Operation Manual will help you to achieve optimal perfor mance with your Jet Kleen Limited by guiding you through the proper steps for setup operation and maintenance of the unit The man...

Page 3: ...chnology air flow system Virtually maintenance free OPTIONS AND ACCESSORIES Wall Mount Bracket Quick Disconnect Swivel Connector Ergonomic Pliable Plastic Chip Guard Pliable Plastic Nozzle Replacement...

Page 4: ...g of the contents of this manual Therefore it is the responsibility of the Equipment Owner to ensure that every operator of this equipment 1 Read understand and observe the procedures recom mended in...

Page 5: ...he closed posi tion rotate the locking ring on the swivel connector Figure 2 counterclockwise 180 until it clicks 2 Push the new nozzle assembly firmly into place 3 Close the locking ring by rotating...

Page 6: ...pressure greater than 3 PSI is legally prohibited in Europe In the US we conform to OSHA Standard number 1910 242 B GOVERNMENT REGULATIONS The Jet Kleen Limited has been designed in accordance with t...

Page 7: ...Feet Set of 4 JKL GA Complete Handle Assembly JK NO Included JKL FMH Hose Without Adapter for Swivel Connector JKL FMHS Hose With Adapter for Swivel Connector JK NO Nozzle JK FE Filter JKL VM Vacuum M...

Page 8: ...ption without charge when returned within 30 days from the date the Return Authorization was issued Specialized Safety Products A W T is not obligated to cover any freight costs Customers must obtain...

Reviews: