Single Gas Sensor Module (SGSM)
Operations Manual
Super Systems Inc.
Page 15 of 38
Page 15 of 51
Register Name
Register Location
Description
MB_READ_PER_SUPER_KN
1210
Super Kn
MB_READ_STANDARD_KN
1211
Standard KN
MB_READ_PROC_VAR
1212
Process variable
MB_READ_GAS_TEMP
1213
Gas temperature
MB_READ_BOARD_ADDR
1214
Board modbus address
(important for slave only)
MB_READ_MODEL_NUM
1215
MODEL number Map as reg 900
MB_READ_SET_FACT_DEF
1216
23205 = Full Defaults
MB_READ_DEGREE_REG
1217
Sets the unit used to display
temperature.
MB_READ_N2_FLOW
1218
N2 flow
MB_READ_NH3_FLOW
1219
NH3 flow
MB_READ_DA_FLOW
1220
DA flow
MB_READ_H2_FLOW
1221
H2 Flow
MB_READ_PV_MODE
1222
Process variable (0 = H2, 1 = DA,
2 = NH3, 3 = Kn, 4 = Standard
Kn)
MB_READ_INPUT_TYPE_REG
1223
Input for voltage inputs
MB_READ_MIN_H2
1225
minimum H2 value
MB_READ_CO2_PRESENT
1226
Amount of CO2 present up to
10%.
MB_READ_PV_REMOVE_NEG
1227
Remove negative number
MB_READ_SET_TAPS_REG
1228
Sets the digital trim pot
MB_READ_UART_1_BAUD_RATE
1229
Baud Rate:
0=1200,...,5=19200,...10=115200.
MB_READ_UART_2_BAUD_RATE
1230
Baud Rate:
0=1200,...,5=19200,...10=115200.
MB_READ_PV_FP
1231
Process variable in floating
point
MB_READ_PELLISTOR_DIAG
1233
Pellistor Diagnostics
MB_READ_AMBIENT_TEMP
1234
Ambient temperature
MB_READ_CJ_TEMP_REG
1235
Cold junction temperature
MB_READ_AD_RAW_VDC
1237
Raw VDC