background image

7

28146 Revision 7

12)

Lastly, make one wire as shown in the picture below. One end will have a female end 
connector connected to relay terminal 3, and the other end will have a ring terminal that will 
attach to a good ground point on the vehicle.

Connect to vehicle ground (-)

Connect to relay

terminal 3

13)

Congratulations, you have completed installation of the vacuum pump! Before you start the 
vehicle, review the simplified wiring diagram pictures below to make sure all of your 
connections are correct:

To ground (-)

Relay terminal 3

To vacuum switch

Relay terminal 1

To (-) pump (black)

Relay terminal 5

(+) 12 volt

Relay terminal 2

To (+) pump (red)

Summary of Contents for 28146

Page 1: ...e received all the parts indicated on the packing slip If you believe anything to be missing or incorrect please call our Customer Service Department at 716 759 8666 PRODUCT WARRANTY This product carries a limited one 1 year warranty against manufacture defects Failure to properly install or use the product as intended or modifying the product and or components of the kit will void the manufacture...

Page 2: ...DED TO COMPLETE THE INSTALL IF YOU FIND YOU ARE MISSING ITEMS PLEASE CONTACT SSBC IMMEDIATELY REGARDLESS OF WHAT DEALER YOU PURCHASED THIS KIT FROM IF YOU HAVE ANY QUESTIONS REGARDING MISSING ITEMS WARRANTY CLAIMS DEFECTIVE ITEMS OR SIMPLY INSTALLATION ISSUES PLEASE CONTACT SSBC DIRECTLY TOLL FREE 800 448 7722 M F 9AM 5PM EST tech ssbrakes com info ssbrakes com ...

Page 3: ...1 First install the pump in a suitable location using the rubber insulators to mount to the vehicle 28146 Revision 7 1 ...

Page 4: ... making sure that the switch is grounded to vehicle IF SWITCH BODY IS NOT PROPERLY GROUNDED THE ELECTRICAL CIRCUIT WILL NOT WORK PROPERLY To brake booster 3 Run vacuum hoses as shown below NOTE Switch is unidirectional Switch will still function if vacuum lines are reversed ...

Page 5: ...SWITCH WITH THE RUBBER HOSES ATTACHED TO IT IS NOT WIRED TO THE POSITIVE SIDE IF VACUUM SWITCH IS WIRED INCORRECTLY THE SWITCH WILL BURN OUT AND WILL NOT WORK Pump Intake Connect to vacuum switch To brake booster 5 Next wire the fuse to a positive ignition switched power source a Positive connection must be a switched source or pump will run with key off b The circuit used for connection must have...

Page 6: ...itch 2 From fuse and to red motor 3 Vehicle ground battery 5 To black motor 1 3 5 2 7 Splice two wires together and connect with a female end connector as show below The female end connector will connect to terminal 2 on the relay one wire to the positive switched power source to fuse and the last wire to the positive pump motor side To switched power To red pump motor To relay terminal 2 ...

Page 7: ...e connector on the other Connect female terminal connector to relay terminal 5 and the female bullet nose connector to the pump motor black side To black pump motor To relay terminal 5 9 Now install vacuum switch clip connector onto the end of a length of wire Make sure to crimp down ends Crimp down ends tightly ...

Page 8: ...ERTS INTO VACUUM SWITCH CONNECTOR ONE WAY DO NOT FORCE PIN INTO BODY MAKE SURE THAT THE CONNECTOR LINES UP WITH PIN ON VACUUM SWITCH WHEN CONNECTING Insert into switch connector 11 Finished assembly should look like the picture below Now connect black vacuum switch connector to top of vacuum switch and connect female terminal to relay terminal 1 Connect to relay terminal 1 Connect to vacuum switch...

Page 9: ...od ground point on the vehicle Connect to vehicle ground Connect to relay terminal 3 13 Congratulations you have completed installation of the vacuum pump Before you start the vehicle review the simplified wiring diagram pictures below to make sure all of your connections are correct To ground Relay terminal 3 To vacuum switch Relay terminal 1 To pump black Relay terminal 5 12 volt Relay terminal ...

Page 10: ...not grounded Check wiring ground Vacuum switch connector not connected Check top of vacuum switch Vacuum pump won t stop Vacuum switch failure Replace vacuum switch Relay failure Replace relay NOTE For frequently asked questions and technical reference information please visit the tech section of our website at www ssbrakes com ...