Warranty 

 
RMCseries  hoist  controller  is  covered  by  a  2-year  manufacturer’s  warranty.  For  extended 
warranty conditions please contact the manufacturer at 

[email protected]

.  

 
Warranty  covers  the  original  factory  installed  components  of  the  controller  and  their  correct 
functioning. 
 
Warranty  voids  if  any  part  or  replacement  components  are  installed  or  modified  without 
authorization  from  the  manufacturer  and/or  the  internal  circuit  is  tampered  or  modified  and/or 
the  controller  is  operated  outside  normal  use  conditions  –  electrical  power  supply  is  not 
conform  or  there  is  connection  error  or  mechanical  damage  of  controller,  including  overload, 
improper use. The manufacturer always helps you with repairing of your unit. 

 
 
 
 
 
 
 

Summary of Contents for RMC12

Page 1: ...12 2014 ATTENTION This instruction manual contains important information about the installation and the use of the equipment Please read and follow these instructions carefully Always ensure that the...

Page 2: ...autions or with specific warnings in this manual violates safety standards of design manufacture and the intended use of this equipment Do not operate in an explosive atmosphere Do not operate this eq...

Page 3: ...he MCseries controller Connect Remote2 E stop connector to the MCseries controller Select type of operation LOCAL REMOTE using the KEY switch Check if the emergency STOP button is not engaged Engage t...

Page 4: ...com sales srslight com 4 4 RMCseries base unit 4 1 RMCseries front panel 4 2 RMCseries rear panel E stop connector NC4FDL Remote A Remote B link connectors are 3 pin NC3MDL NC3FDL or NC3MAH and NC3FA...

Page 5: ...is latching pushbutton switch turns the Hoist Control system off Once the STOP button has been pressed it is locked into the off position and must be rotated clockwise to be released 5 2 GO This pushb...

Page 6: ...E STOP STATUS LED Green E STOP system is OK Orange Indicates that the system needs to be reset Red E STOP is active somewhere in the system RED blinking E STOP button is pressed on the device 5 7 CMC...

Page 7: ...up S 25 Contactor ON a a 26 AC1 24V g g 27 AC1 24V n n 28 AC1 24V p p 29 AC2 24V r r 30 GROUND s s 6 2 E stop connector Unit is equipped with certified SIL3 E STOP safety relay For additional safety u...

Page 8: ...ia network to all linked controllers RS485 is used as a communication link Neutrik NC3FXX MXX Pin 1 Data common Pin 2 Data minus Pin 3 Data plus 6 4 CMC DIGITAL connection CMC remote connectors are us...

Page 9: ...es srslight com 9 7 Linking of RMCseries units Up to 10 RMC base units can be linked together for a group operation of GO buttons For linking of RMC base use a 3 pin XLR cable connected as 1 1 between...

Page 10: ...ata Main Power AC208 230V 50 60Hz T2 5 Optional AC110V 60Hz 8 1 Protections and Safety Dry contacts all outputs are galvanic isolated Double Recessed Emergency stop SIL3 safety module Double encoded d...

Page 11: ...rs the original factory installed components of the controller and their correct functioning Warranty voids if any part or replacement components are installed or modified without authorization from t...

Page 12: ...ybnicna 36 D SK 83106 Bratislava Slovak Republic www srslight com sales srslight com 421244681417 Declares that the product Name of product RMCseries hoist controller RMC8 RMC12 and variants Types RMC...

Page 13: ...panel 4 4 5 Optional CMC DIGITAL remote 5 5 5 1 STOP 5 5 5 2 GO 5 5 5 3 DIRECTION SWITCHES 5 5 5 4 DIRECTION SWITCH LED 5 6 5 5 STATUS LED 5 6 5 6 E STOP STATUS LED 5 6 5 7 CMC DIGITAL Remote connecto...

Reviews: