Remote1/Remote2 connector or LINK connectors
LINK connectors are used for linking of two or more RMC units together in case that linked operation
of units is required. For link unit need be in the local mode. E-STOP and GO signal is sent via network
to all linked controllers.
RS485 is used as a communication link.
Neutrik NC3FXX/MXX Pin 1: Data common
Pin 2: Data minus
Pin 3: Data plus
CMC-DIGITAL connection
CMC remote connectors are used for linking of RMC with the CMC-xx DIGITAL remote for remote
operation with option to change directions. Each RMC needs to be connected with CMC-xx DIGITAL
via 5pole digital cables.
STOP and GO signal is sent only to controller – not to other linked units.
RS485 is used as a communication link.
Neutrik NC5FXX/MXX Pin 1: Data common
Pin 2: Data minus
Pin 3: Data plus
Pin 4: DC1
Pin 5: DC2