Srne IU Series User Manual Download Page 4

06

Non-isolated TTL communication, power supply 12.5V/200mA

Switch on or off by control equipment such as external 

relay and mechanical switch

Adjust the 3rd position rocker switch 

to ON when using this function

Non-isolated RS485 communication, power supply 

5VDC/200mA, remote switch of interface integration 

No input reverse connection 

protection!

Positive terminal 5.0 VDC

Definition

D+

D-

Power ground

SW1

SW2

CANH

CANL

05

06

2. Specification

Remarks

Product model

IU12-2KW

IU24-3KW

Rated output power W

2000W

3000W

Rated output power VA

2000VA

3000VA

Withstand instantaneous impact power

4000W

6000W

Rated output voltage

110VAC/120VAC(±3%)

Default: 1

2

0 V, adjusted by 

communication

Output frequency

50/60HZ(±0.2%)

Default: 

6

0 HZ, adjusted by 

communication

Output wave

Pure sine wave

Output harmonic component

THDV < 4% (pure resistance load)

Load power factor

0.2-1 (load power ≤ output continuous power)

Rated input voltage

12VDC

24VDC

Input voltage range

10.8~16.0VDC

21.6~32.0VDC

Rated output efficiency

>89.0%

>90.0%

Maximum output efficiency

> 92.0% (30% overload)

> 93.5% (30% overload)

Standby current

<0.2A

<0.12A

OFF

No-load current

<1.0A

<0.95A

       ON, No load

RS485 communication

and CAN communication function (optional)

USB interface

Dual USB output, 5VDC/2A

ON/OFF/ECO mode

ON - AC normal output

OFF - no AC output, standby

ECO - energy-saving mode, auto switch

ECO starting power

30W

30-100W (adjustable)

ECO interval time

1min

30s-30min (adjustable)

TTL interface

Indicator

Green - normal operation; Red - fault

External switch contact interface

Protection function

Input over-voltage/over-discharge protection, output 

overload/short-circuit protection, and device over-

temperature protection

Operating ambient temperature

Storage ambient temperature

-35

~80

Relative humidity

≤95%

Protection grade

IP20

Heat-dissipating method

Natural heat dissi intelligent air cooling

Noise

≤60dB

Product dimension

406*300*115mm

Installation dimension

230*284*φ5mm

Net weight

5.3kg

-20

~60

(1) Default baud rate: 9,600 bps, check bit: none, data bit: 8 bit, stop bit: 1 bit
(2) Interface type: RJ45, communication power supply output specification: 5VDC/200mA
(3) The RS485 communication line sequence is defined as follows, with interface integrating 
remote switch interface (SW1/SW2) and CAN communication interface. When the switch 
interface (SW1/SW2) is floating and open circuit = OFF mode; when the switch interface 
(SW1/SW2) is short-circuited = ON mode.

3. Description of interface function

S/N

3.1 RS485 communication

Dual USB output interface with a total output capacity of 5V 2A is capable of charging mobile phone/

PAD and other mobile devices, and no output when the battery is over-discharged or with over-voltage.

S/N

Definition

USB+5.0VDC

NC

NC

USB-

1) Default baud rate: 9,600 kps; parity bit: none; data bit: 8 bit; stop bit: 1 bit
2) Communication power output specification: 12.5 V/200 mA

S/N

Description

VCC communication power supply output

RX - inverter data receiving end

TX - inverter data sending end

GND - power ground

3.2 USB interface

3.3 TTL communication interface

Summary of Contents for IU Series

Page 1: ...Manual version V1 01 Subject to change without notice IU Series Pure Sine Wave Inverter High Frequency User Manual Code 107058...

Page 2: ...l not disassemble the inverter themselves Please contact our professional maintenance personnel for repair 2 Do not place the inverter within the reach of children 3 Do not install the inverter in har...

Page 3: ...ility Advanced SPWM technology for pure sine wave Advanced wave lter and current limiting technology with impact load such as large capacitive and inductive available Various output sockets to satisfy...

Page 4: ...30min adjustable TTL interface Indicator Green normal operation Red fault External switch contact interface Protection function Input over voltage over discharge protection output overload short circu...

Page 5: ...inverter over current abnormal OFF Normal ON 1 HZ buzz Slow ash Slow ash No buzz OFF Single ash 1 HZ buzz De nition of indicator ashing 1s ON 1s OFF in 2s 0 1s ON 1 9s OFF in 2s 0 1s ON 0 1s OFF 0 1s...

Page 6: ...evice or cause unpredictable danger The AC output is a high voltage so please do not touch the wiring Do not touch the working fan to prevent injury It is necessary to con rm that the inverter is the...

Page 7: ...AC power output is normal 4 4 Close the circuit breakers on the AC load line turn on the AC load one by one and check the operating status of the inverter and the load 4 5 If the fault indicator is re...

Page 8: ...he fan works properly Red light ashing quickly green light off buzzer buzzing no AC output Over high battery input voltage 1 Mismatch between battery voltage and device system voltage Measure the posi...

Reviews: