L: Live wire
N: Neutral wire
Correctly connect the AC output live and neutral wires according to the wire
sequence and terminal locations shown below, and connect the earth wire to the grounding
screw hole through the O-type terminal.
L: Live wire
N: Neutral wire
Note: Try to use a thick earth wire (wire cross-sectional area is not less than 4mm2), the
grounding point should be as close as possible to the machine, and the shorter the grounding
wire the better.
PV
input wiring method:
Before wiring, disconnect the circuit breaker first, and confirm whether the wires
used are thick enough. Please refer to Section 2.2 Wiring Specifications and Circuit
Breaker Selection".
Correctly connect the PV input wires according to the wire sequence and terminal
All-in-one Solar Energy Storage Inverter Controller