Test the Bleed
T e s t t h e B l e e d
Use a 13 mm socket to manually lock out the damper. Push down on
Use a 13 mm socket to manually lock out the damper. Push down on
the damper assembly to test the bleed. The shaft should not move
the damper assembly to test the bleed. The shaft should not move
more than 2 mm if the bleed was successful.
more than 2 mm if the bleed was successful.
If the shaft moves while locked out, repeat the bleed section.
If the shaft moves while locked out, repeat the bleed section.