SR Instruments SRScales SRV947R Operating And Service Manual Download Page 6

Model SRV947R-BT 24 X 48 Remote Display Platform 
Operating and Service Manual 
Part No. MAN947R-BT_210610 

 

Page 6 of 18 

 
 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel: 716-693-5977     Fax: 716-693-5854    URL: 

www.srscales.com

 

email: 

[email protected]

     

  

Copyright 2021

 

S

Instruments, Inc. 

SPECIFICATIONS 

 

 

MAXIMUM WEIGHT CAPACITY 

400 lb / 182 kg 

PLATFORM SIZE 

24 in x 48 in x 2 in 
(61 cm x 122 cm x 5 cm) 

DISPLAY TYPE 

1.0” LCD display with 5 active digits 

DISPLAY RESOLUTION 

0.2 lb / 0.1 kg 

ACCURACY 

0.2% +/- 2 digits of displayed resolution for calibrated 
range 

AUTO ZERO 

One button operation 

AUTO WEIGH 

Scale will automatically turn on and lock in on a stable 
weight. 

AVERAGING 

Automatic digital filter 

POWER SUPPLY 

AC Wall Power Supply (Medical Grade)

 

CALIBRATION 

Calibration is traceable to NIST standards 

 

OPERATING CONDITIONS 

Normal operating conditions for this product: 
Ambient Temperature Range: 68

F to 85

F (20

C to 

30

C), Relative Humidity Range: 0%-85%.  Avoid 

exposure to high-pressure water or steam.

 

 

TRANSPORT and STORAGE 

Storage and transport conditions should not vary 
outside the following conditions:  Relative Humidity 
0% to 85%, Ambient Temperature 14

F to122

F (-10

to +50

C).  Remove batteries if storing longer than 

three (3) months. 

BLUETOOTH REQUIREMENTS 

Refer to 

the SR Scales App

 on the Google Play store 

for further information. Minimum requirements for an 
OS level of android device are listed at the Google play 
store 

Summary of Contents for SRScales SRV947R

Page 1: ...610 Page 1 of 18 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc SRV947R BT REMO...

Page 2: ...F CONTENTS TABLE OF FIGURES 2 PACKING CHECKLIST MODEL SRV947R BT 3 ASSEMBLY 3 SYSTEM DESCRIPTION AND INTENDED USE 4 STORAGE AND TRANSPORTATION 4 CLEANING AND DISINFECTING 5 SPECIFICATIONS 6 BUTTON FUN...

Page 3: ...rsonnel The mounting hardware provided will cover most wall applications B Determine a position on the wall comfortable to the user Mark the location of the two 2 mounting holes on the wall holes are...

Page 4: ...patient s weight The patient s weight is displayed on an LCD screen With a push of a button weight data may be viewed in either pounds or kilograms INTENDED USE The SRV947R BT Portable Platform Scale...

Page 5: ...act areas Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available...

Page 6: ...matically turn on and lock in on a stable weight AVERAGING Automatic digital filter POWER SUPPLY AC Wall Power Supply Medical Grade CALIBRATION Calibration is traceable to NIST standards OPERATING CON...

Page 7: ...ts com Copyright 2021 SInstruments Inc MODE ZERO HOLD RECAL L BUTTON FUNCTIONS Figure 1 SRV947R BT Button Label The ZERO WEIGH button is used to clear the Recall memory and start a new weighing cycle...

Page 8: ...en pounds or kilograms The system will remain in the same mode as last used unless manually changed WEIGH The WEIGH button is used to clear the Recall memory and start a new weighing cycle HOLD RECALL...

Page 9: ...or remote wireless operation Use your Android device to display weight and control the SRV947R BT scale functions Figure 2 Ensure your remote display indicates CONNECTED before use The WEIGH button wi...

Page 10: ...lified by the operational amplifier The output of the operational amplifier is digitized by the analog to digital converter The converter integrates the analog signal onto the integrating capacitor ov...

Page 11: ...semiconductors on the printed circuit boards may be damaged by electrostatic discharge ESD Be sure to use proper handling precautions at all times IMPORTANT CALIBRATION CHECK Qualified service person...

Page 12: ...r a parameter saved NOTE Ensure that nothing is in contact with the scale system during this procedure Remove hands from the system when noting the displayed calibration results CAL MENU data Displays...

Page 13: ...the digits using the Right Button until desired value is shown Press the Left Button and continue the same with the remaining digits d Press the Left Button to save or Right Button to toggle to quit S...

Page 14: ...Press the Left Button again to save and the display will show SAV d Calibrate using the Three Point Calibration Curve zero half scale and full scale NOTE The scale can also be calibrated with a Two p...

Page 15: ...ECTIVE ACTION Weight reading is much lower than expected Check that the platform is clean underneath stand on each of the four corners to see if one corner is not weighing correctly System fails to pe...

Page 16: ...rm Operating and Service Manual Part No MAN947R BT_210610 Page 16 of 18 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstrume...

Page 17: ...ay lay flat on a desk or end table If desired provisions for wall mount have been incorporated and can be accomplished in the manner described below A The display should be installed by qualified pers...

Page 18: ...ual Part No MAN947R BT_210610 Page 18 of 18 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInst...

Reviews: