background image

Model SRV411

i

 Small Animal Floor Scale 

Service Manual 
Part No. MANSRV411

i

_210112 

Page 7 of 16 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel: 716-693-5977     Fax: 716-693-5854    URL: 

www.srscales.com

 

email: 

[email protected]

     

  

Copyright 2021

 

S

Instruments, Inc. 

BUTTON FUNCTIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 1: SRV411

i

 Button Label 

 
 

HOLD/RECALL BUTTON 

Scale will automatically lock a stable weight that is greater than five pounds and “MEM” will be 
displayed in the upper left of the display. To manually hold a weight reading at any time during 
the weighing process, press the “

Hold/Recall

 

button.

 

To recall a weight in memory, press the

 

Hold/Recall

 

button after the display has powered down or with less than five pounds on the 

scale. 

NOTE: 

When the scale is off, pressing any of the buttons will turn on the scale. Press and hold 

the 

“Zero/Weigh” 

button to erase the last held weight from memory. 

 

LB / KG BUTTON 

Weight data may be viewed in either pounds or kilograms. Pressing the “

lb/kg

” button allows 

the operator to toggle between the two readings. 

 

ZERO / WEIGH BUTTON 

The “

Zero/Weigh

” button is used to zero the system before using the scale system. Ensure that 

nothing is in contact with the weighing surface during this procedure. The display will read “

0.0 

Lb

” (or 

0.0

 

kg

). 

The  “

Zero/Weigh

”  button  also  wakes  up  the  display  and  shows  the  weight  if  it  should  Auto 

Power Down before the weighing process is done.

 

NOTE

: When system is zeroed, the Hold/Recall memory is erased. 

 

Summary of Contents for SRSCALES SRV411i

Page 1: ...210112 Page 1 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc S by S Instr...

Page 2: ...nstruments Inc TABLE OF CONTENTS PACKING CHECKLIST Model SRV411i 3 ASSEMBLY 3 SYSTEM DESCRIPTION and INTENDED USE 4 MAINTENANCE and CLEANING 5 STORAGE and TRANSPORTATION 4 SPECIFICATIONS 6 BUTTON FUNC...

Page 3: ...personnel The mounting hardware provided will cover most wall applications B Determine a position on the wall comfortable to the user Mark the location of the two 2 mounting holes on the wall holes ar...

Page 4: ...cers are strategically placed to ensure an accurate representation of the small animal s weight The small animal s weight is displayed on a LCD screen With a push of a button weight data may be viewed...

Page 5: ...e a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disinfectan...

Page 6: ...tion for calibrated range AUTO ZERO One button operation AUTO WEIGH Scale will automatically turn on and lock in on a stable weight AUTO POWER DOWN After 1 minute AVERAGING Automatic digital filter PO...

Page 7: ...Recall button after the display has powered down or with less than five pounds on the scale NOTE When the scale is off pressing any of the buttons will turn on the scale Press and hold the Zero Weigh...

Page 8: ...the Zero Weigh button and wait for the display to indicate ZERO Release the Zero Weigh button and the display will read 0 0 Position the small animal on the platform Weight will be displayed in a few...

Page 9: ...ge applied to the converter The residual voltage on the integrating capacitor is then multiplied by a factor and again discharged at a rate proportional to the reference voltage The residual voltage f...

Page 10: ...curacy Automatic Shut Off is shipped with a factory default of 60 seconds If a longer period of time up to 900 seconds is desired then it will need to be re set Both procedures are found below Access...

Page 11: ...curve zero half and full scale save Saves the calibration data quit Quits without saving the calibration data Enter CAL Mode To enter the CAL mode press the calibration button Figure 2 using the poin...

Page 12: ...play default weight b The display will show only the five digits XXXX X with the thousand place flashing 1 Select past to the next digit by pressing the Left Button c Once in the hundreds place set th...

Page 13: ...e Left Button to save and the display will show SAV d or press the Right Button to toggle to quit and then press the Left Button to exit without saving changes f Press the calibration button Figure 2...

Page 14: ...ties on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event...

Page 15: ...on a desk or end table If desired provisions for wall mount have been incorporated and can be accomplished in the manner described below A The display should be installed by qualified personnel The mo...

Page 16: ...MANSRV411i_210112 Page 16 of 16 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2021 SInstruments Inc...

Reviews: