8. Operating Control Instruction
Master/Slave:
Master: The master should always working as a master as long as it is not set in a DMX mode whate-
ver other modes it is. And it send out the signal so that the slave synchronous with it. To avoid the
host signal and DMX512 signals interfere with each other, should cut off the DMX512 signals. The
signal lines are longer than 60 meters(20 lamps) ,should increase a signal amplifier.
Slave: he Slave must be set in DMX mode and the address code should be A001, to assure receive the
master’s signals correctly. Only one light can be set as a Master and others are slaves.
Note: This product uses input and output power cord 2.5 qm copper core wire, power line in
series, when 220V AC should less than 45 lights, and 110V AC less than 25 lights! ! !
9. XLR cable connecting
XLR cable:
The standard connection way of the XRL is: one end connect to the male plug ,and the other connect
to the female.
Noted: In order to avoid failures and interference signal transmission, we connect a
resistance120Ω
(1/4W)at the end of the DMX connecting as below: