background image

 

 

 

 

Product Feature 

 

 

2 kinds of running model 

  External control mode (Slave model) 

  DMX 512 controller control(2 kinds channel modes) 

  Master/salve  model  control  (auto  match  the  signal  from  controller  and  the  Master 

light, no need to set by menu) 

  static mode (Master model)

 

  It can fix any color without the controller ,also work this color with strobe 

 

Non-linear dimmer and linear dimmer 

  The speed of dimmer can be set under the controller control 

 

Screen Protect 

  It will enter blank screen without any operate on the keyboard in 30 seconds . Press any 

keys then it can quit screen protection.   

 

Temperature Protection 

  It can be set to temperature protection mode 

 

Speed of the Fan 

  The fan will start to work when the working temperature reach 40 degree, and the speed 

will be changed according to the change of temperature. 

 

Can be Reverse display 

 
 

Multi-light working in the same time 

When  using  controller  to  control  multi  lights  to  work  in  strobe,  the  controller  just  send  the 

channel data . The strobe effect will be depend on each light itself . And please take attention for 
the follow situation: 

 
1. There will be many situations make the lights are not synchronization in the beginning. (For 

example:  the  different  time  of  opening  the  light  ,  or  different  time  of  them  connect  to  the 
controller) .In this case,    you can change value of the controller( for example push 20 to 0, and 
back to 20), then it can be synchronization. 

2. Due  to  crystal  frequency  of  different  lights  are  not  the  same  exactly,  so  it  may    not  be 

synchronization after long time. 

3. If need to keep synchronization for long time, there are two ways to do so: 

              A. Using the controller to edit program make the strobe, auto run effect,then they must be 
synchronization. 
              B. Using the Maser/Slave model 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SquareLED Zyclone 300W RGBAL

Page 1: ...User Manual Squareled Zyclone 300W RGBAL IP65 ...

Page 2: ... SquareLED Zyclone 300W RGBAL User Manual IP65 ...

Page 3: ...e must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually Please don t project...

Page 4: ...is designed and manufactured strictly following CE RoHS standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for operation And it is applicable for large scale live performances theater studio nightclubs and discos The SquareLED Zyclone 300W RGBAL adopts 1PCS 300W COB LED available for RGBAL which features high brightn...

Page 5: ...Beam Angle 15 to 30 Fully Tuneable from 2 700 to 12 000K Zoom Function Auto zoom by DMX Shutter controlled by DMX auto cutting to any shapes Die casting aluminum housing design 4 kinds of dimming curve Dimming Frequency 500HZ 25000HZ optional Strobe 1 25times sec High quality optical system glass reflector 5 22 DMX channels Control Protocol RDM DMX Auto run and Master Slave control system LCD with...

Page 6: ... other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connection with DMX terminator 4 DMX INPUT DMX OUTPUT POWER IN ...

Page 7: ...e it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 1 2 3 1 Ground 2 Data 3 Data COMMON DMX DMX 120Ω Pin2 Pin3 ...

Page 8: ...d according to the change of temperature Can be Reverse display Multi light working in the same time When using controller to control multi lights to work in strobe the controller just send the channel data The strobe effect will be depend on each light itself And please take attention for the follow situation 1 There will be many situations make the lights are not synchronization in the beginning...

Page 9: ...identify controller signals or master signals Manual M MC M stand for Master mode MC stand for Mixed Colort Auto run M Ax M stand for Master mode A stand for Auto x is Auto program number 1 8 Sound activated M Sx M stand for Master mode S stand for Sound x is Sound activated 1 or 2 Color temperature M WP M stand for Master mode WP stand for White Point Selection Color M QC M stand for Master mode ...

Page 10: ...y of OK to choose mode Choose the color and strobe setting Auto Mode Same as above Choose the Auto and Speed setting Sound Mode Same as above Choose the Sound and Mode setting White Point Same as above Choose the color temperature Quick Color Same as above Choose the built in color Motor Control Same as above Can control the Motor Status Menu Description Software Name of software Version Version T...

Page 11: ...mmer frequency 500Hz 25000Hz Dimmer Curve Change dimmer curve Standard Incandescent Linear Quick Over Temperature Temperature setting 80 100 Each 5 for increase or decrease Backlight Adjust the display brightness 10 100 Each 5 for increase or decrease Backlight Timeout Screen protect setting No screen protect or black screen from 0 60 second Each 5 for increase or decrease Load Factory Settings Re...

Page 12: ...80 89 Auto run 8 90 199 No function 200 219 Sound control 1 220 255 Sound control 2 11 0 255 M1 M2 position control 12 0 63 M1 M2 Control straight up and down by channel 11 64 127 M1 M2 Angle adjustment big data big angle 128 191 M1 M2 back to original position 192 255 M1 M2 Reverse angle adjustment big data big angle 13 0 255 M3 M4 position control 14 M3 M4 position control refer to channel 12 15...

Page 13: ...e sure to put the safety chain and check whether the screws are screwed properly when installing the fixture Make sure the lens are in good condition It s recommended to replace the units if there are any damages or severe scratch Make sure the fixture is operated by qualified personnel who knows the fixture before using Keep the original packages if any second shipment is needed Don t try to chan...

Page 14: ...eye bolt on the back of the fixture to which the safety chain or cable can threaded through and then hung from the secondary point Make sure the Gel frame Gel holder is clipped into position correctly and cannot come loose If you are not qualified or have any doubts about hanging the led profile spotlight then do NOT hang it Do not clamp the safety cable to the U bracket or clamp That is not a sec...

Page 15: ...d dirt everywhere The fans keep the LED cool and keep the electronics cool too Without the fan working efficiently and dust free the fixtures will fail and that will be a lot more costly than having someone vacuum the fixtures on a regular basis How often should the fans be cleaned It depends on where the fixtures are in a very dusty atmosphere once a week So check the fans on a regular basis they...

Page 16: ...Das LichttechnikhausVertriebs GmbH Rudolf Diesel Str 3 D 89312 Günzburg Telefon 49 0 82 21 207 98 0 Fax 49 0 82 21 207 98 69 E Mail info lth gmbh de Web www lth gmbh de ...

Reviews: