Manual | Hi-Precision 300W LED Profiler MK2 fixed
Horizontal place:
Lens cone install as shown in the figure below.
1. Arrow and knob aligned in a straight line
Arrow and knob aligned in a straight line
2. Put lens cone to the box and rotate clockwise
3. Clockwise to stop after the knob on the lens cone and keep in the same line,
and makes the knob body fasten.
4.2 Power connection
•
Power cable use 2.5 mm2 copper core.Power in series, the 220V AC power is no more than
8 lamp, Using a 110V AC power can’t more than 4 lamps;
•
DMX512 signal cable connect 20pcs fixtures Max; When the distance between console and
fixture, or distance between two fixtures, longer than 50M then add a signal amplifier is very
necessary.
•
Recommend to plug a terminal in signal output socket of the last fixture, which connected in
the end of each signal transmission line. To weld a 120Ω / 1W resistor between the male plug
2 and 3 feet to make a terminal plug. The usage is to reduce the reflected wave interference
caused by the end of control signal cable‘s circuit open.