background image

Manual |  Hi-Precision 300W LED Profiler MK2 fixed 

Horizontal place:

 Lens cone install as shown in the figure below.

1.  Arrow and knob aligned in a straight line 

Arrow and knob aligned in a straight line

2. Put lens cone to the box and rotate clockwise

3.  Clockwise to stop after the knob on the lens cone and keep in the same line,  

and makes the knob body fasten.

4.2 Power connection

• 

Power cable use 2.5 mm2 copper core.Power in series, the 220V AC power is no more than  
8 lamp, Using a 110V AC power can’t more than 4 lamps;

• 

DMX512 signal cable connect 20pcs fixtures Max; When the distance between console and 
fixture, or distance between two fixtures, longer than 50M then add a signal amplifier is very 
necessary.

• 

Recommend to plug a terminal in signal output socket of the last fixture, which connected in 
the end of each signal transmission line.  To weld a 120Ω / 1W resistor between the male plug 
2 and 3 feet to make a terminal plug. The usage is to reduce the reflected wave interference 
caused by the end of control signal cable‘s circuit open.

Summary of Contents for Hi-Precision 300W LED Profiler MK2 fixed

Page 1: ...SquareLED Hi Precision 300W LED Profiler MK2 fixed Focus ...

Page 2: ...nch colorfullLCD display 1 2 Mechanical and physical parameters Light source 300W COB Light Color Light source White ColorTemperature 3200K 5600K Color Rendering Index 90 Beam Angle 5 10 14 19 26 36 50 optional Luminum 13000LM Dimmer 0 100 Strobe 0 20Hz 1 3 3Mechanical and physical parameters Case Material Die casting aluminum aluminum Plastic Protection Grade IP22 WorkingTemperature 20 40 C Noise...

Page 3: ...Manual Hi Precision 300W LED Profiler MK2 fixed 2 Illumination Chart 2 1 5600K Illumination ...

Page 4: ...ed to install and maintain this equipment This equipment has passed strict inspection before delivery Users have to obey the safety and notice guide The manufacturer will not responsible for any not according to the instruction normal operation and without permission Since the change of equipment and damages caused by any accident ...

Page 5: ...amp bracket as shown in the figure below Hanging place Notice ensure the installation position is completely suitable for this product to ensure safe and reliable installation location Use and install the equipment must be far away from flammable items to ensure to keep a distance of 0 3 meters and flammable materials Use the right tools to fix the lighting equipment in the proper installation loc...

Page 6: ...connection Powercableuse2 5mm2coppercore Powerinseries the220VACpowerisnomorethan 8lamp Usinga110VACpowercan tmorethan4lamps DMX512signalcableconnect20pcsfixturesMax Whenthedistancebetweenconsoleand fixture ordistancebetweentwofixtures longerthan50Mthenaddasignalamplifierisvery necessary Recommendtoplugaterminalinsignaloutputsocketofthelastfixture whichconnectedin theendofeachsignaltransmissionlin...

Page 7: ...xed 4 3 DMX512 Console Connect SerialconnecttheDMX512consoleandsignalcable DMX512addresscodeisreusable DMX512addresscodecanbeanynumberbetween001to512 5 Operation 5 1 DisplayWindow Dot icon for DMX signal instructions do not display when no signal ...

Page 8: ... Function to the next level submenu and save or confirmation settedfuction data UP Select function sub menu up cycle adjustment data DOWN Choose function submenu circulate down to adjust the data values MENU Return to a layer on the menu or switch to the main menu ...

Page 9: ... edit state Press UP DOWN or Rolling hand wheel to set DIM setting data is 0 255 STROBE setting data is 0 20Hz Press ESC or RETURN to back to main menu and save automatically 5 4 DMX512Address code setting ADDR Press UP DOWN or Rolling hand wheel to ADDR Press ENTER to edit state Press UP DOWN to choose the address code between 001 to 512 Press ESC or ENTER to back to main menu ...

Page 10: ...al choose mode Press DIMMING to setting mode for linear 6 DMX512 Console channel chart Channel No Channel value Command function 1 0 255 White 0 100 dimming 2 0 5 No function 6 255 0 20Hz Strobe 3 0 10 Internally dimming speed 11 40 Linear dimming speed4 41 70 Linear dimming speed3 71 110 Linear dimming speed2 111 140 Linear dimming speed1 141 170 Turn off linear dimming 171 255 No function ...

Page 11: ...Hi Precision 300W LED Profiler MK2 fixed Das LichttechnikhausVertriebs GmbH Rudolf Diesel Str 3 D 89312 Günzburg Telefon 49 0 82 21 207 98 0 Fax 49 0 82 21 207 98 69 E Mail info lth gmbh de Web www lth gmbh de ...

Reviews: