background image

Page 11

English Manual

1019621-A

Use and Care

!

 READ BEFORE USING

CALIBRATION

The SPYDSS-9G is equipped with a Hypro DeflecTip wide-angle flat flood nozzle. The table below will serve as a ref-

erence for application rates. A working pressure of 15-20 psi will provide adequate coverage. The nozzle should be 

adjusted to provide a 60-65 inch spray width with a 4-6 inch overlap of the previous spray pass.

Hypro Nozzle 

Number

Pressure  

PSI

Capacity  

GPM

Gallons per 1000 Sq. Ft.

2 mph

3 mph

4 mph

5 mph

30DT7.5

10

0.8

0.9

0.6

0.4

0.3

15

0.9

1.0

0.7

0.5

0.4

20

1.1

1.2

0.8

0.6

0.5

30

1.3

1.5

1.0

0.7

0.6

Confirming Application Rate

Because walking speeds vary, it is always best to perform a field test to confirm the application rate. The 

procedure is simple:

1.  Measure an area at least 10,000 square feet.
2.  Fill the tank with water.
3.  Spray the measured area at 20 psi and at a  

comfortable sustainable walking speed.

4.  Refill the tank from a calibrated container keeping  

track of the amount needed to refill the tank.

5.  Divide the number of gallons used by the square footage  

of the area sprayed  

(Expressed in 1000 square foot 

increments).

6.  Since the tank holds 9 gallons, divide 9 by the result to obtain 

the expected coverage per tank full.

Example: 

4.5 gallons used
10,000 square feet sprayed

    9 gallons  /    

0.45

    =  

20

The capacity is 9 gallons, so in this 

example a full tank should cover 

20,000 square feet.

    4.5 gallons  /  10   
=    

0.45

   gallons  /  1,000 square ft.

Summary of Contents for SPYDSS-9G

Page 1: ...ngle Nozzle SPYDSS 9G Drop In Sprayer IMPORTANT This manual contains information for the safety of persons and property Read it carefully before assembly and operation of the equipment OPERATOR S MANUAL Spyker Spreaders Contact us at 800 972 6130 www spyker com ...

Page 2: ... set up procedure is as follows Remove all contents from inside the tank Remove all contents from the box Report any missing or damaged items to your dealer immediately TABLE OF CONTENTS Safety 2 Parts 3 7 Assembly 8 9 Use and Care Operation Maintenance 10 Battery Recharging 10 Initial Start Up Pressure 10 Calibration 11 Troubleshooting 12 Accessories 13 Warranty 14 Observe all safety precautions ...

Page 3: ... 1 1019634 1 Angle Bracket 2 1019635 2 Wing Nut 3 1019636 2 Mounting Clip 4 1019637 2 Screw 6 x 1 2 5 1019638 2 Pan Head Screw 6 1019639 2 Fender Washer 7 1019640 2 Eye Bolt 1019641 2 Eye Bolt Optional Alternate H C Battery 8 1019691 1 Extension Wand 9 1019692 1 Trigger Jet Valve 10 1019693 1 Turbo TeeJet Nozzle Tip 11 1019694 1 Cap Nut 12 1019695 1 Angle Adapter 13 1019654 1 Strainer w Check Valv...

Page 4: ...ty Description 14 1019642 1 Toggle Switch 15 1019643 1 Switch Bracket 16 1019644 1 Pump Switch Wiring Assembly 17 1019645 1 Screw Clamp 18 1019646 1 Battery 1019647 1 Battery High Capacity 19 1019648 1 Battery Wiring Assembly 1019649 1 Battery Wiring Assembly Optional H C Battery 20 1019650 1 Fuse Holder N A 1019651 1 20 Amp Fuse 14 16 17 15 19 16 18 20 ...

Page 5: ... 4 NPT x 3 8 Male 22 1019653 1 Single Swivel Adapter 23 1019654 1 Strainer w Check Valve 24 1019655 1 Cap 25 1019656 1 Wide Angle Spray Tip 26 1019657 1 Clearbraid Hose 3 8 ID x 20 27 1019637 2 Screw 6 x 1 2 28 1019636 2 Spring Clip 29 1019660 2 Easy Seal Clamp For 3 8 ID Hose 30 1019661 1 3 8 Wing Nut Barb Steel 51 B 6395 1 Cable Tie Not Illustrated here 22 23 25 24 26 29 30 21 27 28 ...

Page 6: ...19662 1 Poly Tank 9 Gallon 32 1019663 1 Regulator 33 1019664 1 0 60 SS Liquid Filled Gauge 34 1019665 4 1 2 Close Nipple Hex 35 1019666 4 1 2 MPT x 1 2 Barb NOTE Two of the four Barbs are not visible in this photo as they are located inside the tank 36 1019668 2 1 2 Female Tee Part list continues on page 7 34 44 43 42 41 34 46 47 48 34 40 33 32 31 35 37 39 38 36 50 49 ...

Page 7: ...l 1019676 1 1 2 ORS x 1 2 Barb Elbow Optional Part 42 1019677 1 Clearbraid Hose 1 2 ID x 10 43 1019713 1 Banjo Strainer 1 2 50 Mesh Complete 44 1019681 1 Barb Elbow 1 2 MPT x 1 2 Barb Elbow 45 1019682 1 6 Female Tank Lid with Vent 46 1019683 4 Machine Screw SS 10 24 x 1 47 1019684 1 Ball Valve 1 2 FPT x 1 2 MPT 48 1019685 1 Street Ell 1 2 49 1019686 1 NPT Reducer Bushing 1 2 x 1 4 50 1019687 1 Ret...

Page 8: ...gnut 30 to the ball valve 47 Fig 3 31 2 Attach the spring mounting clips 28 to the hopper near the vertical centerline with the supplied screws 27 Fig 2 28 27 4 Snap the hose 26 into the clips 28 with the nozzle facing forward Referencing the photo below Align the nozzle end of the hose 26 against the spreader frame A Secure with a cable tie 51 NOTE The nozzle must be facing forward 28 26 Fig 4 A ...

Page 9: ...auge hand tight with only sufficient force to prevent leaking Overtightening the gauge can break the regulator housing 32 Fig 9 9 Install the pressure gauge 41 5 Align the thumb switch 15 with the handle B and attach with a screw clamp 17 Fig 5 15 17 6 Install the pump wiring assembly clips 16 to the thumb switch spades 15 Fig 6 15 16 Assembly is complete B 19 19 40 41 41 32 ...

Page 10: ...ry can also be recharged by the service truck s charging system by using the optional vehicle charging kit INITIAL START UP PRESSURE TESTING 1 Turn the pressure regulator knob counter clockwise all the way 2 Put about one gallon of water in the tank for testing 3 Be sure that the spray line valve is turned off 4 Turn on the handlebar thumb switch You should hear the pump running and see water movi...

Page 11: ...on Rate Because walking speeds vary it is always best to perform a field test to confirm the application rate The procedure is simple 1 Measure an area at least 10 000 square feet 2 Fill the tank with water 3 Spray the measured area at 20 psi and at a comfortable sustainable walking speed 4 Refill the tank from a calibrated container keeping track of the amount needed to refill the tank 5 Divide t...

Page 12: ...ulty or missing Check Replace gasket Broken fitting or hose Repair as necessary Pump needs repair Repair as necessary Plugged intake line Remove obstruction Pump has lost prime Re prime the pump by backing the Pressure Regulator all the way out Pump will not turn on Battery dead Recharge battery Loose or faulty connection Repair as necessary Faulty switch Repair as necessary Nozzle not spraying Sp...

Page 13: ... TCG The charger allows the sprayer battery to be recharged from a truck charging system in between jobs Included is 20 feet of 10 gauge x 2 wire 40 amp circuit breaker battery wire connectors and a quick connect modular plug for the battery ACCUMATE CHARGER KSP18 C12G 110 Volt powered plug in charger for overnight recharging This is a top quality charger designed specifically for AGM batteries TR...

Page 14: ... ited to consequential or incidental damages arising from the operation condition or use of the item The sole and exclusive remedy against Spyker Spreaders being the replacement of the defective parts This warranty gives you specific legal rights and you may also have other rights which vary from state to state This express warranty which is applicable only to the original purchase is in lieu of a...

Reviews: