Safety Setup
(menu option)
From the initial menu screen select Safety Setup using the Plus and Minus button and press Enter.
Safety Relay:
This setting determines the operation of the Safety Relay during an error condition. Once the error condition is
corrected the device will return to normal operations.
Options:
DISABLED
This option is the default setting. Safety relay is not enabled.
ON ANY ERROR
During an
y error condition it triggers the Safety Relay. High/Low alarms will also shut off the output.
H-ALARM ONLY
During a
High Alarm error condition it triggers the Safety Relay. Low alarms will beep but will not activate the
safety relay and power will continue.
The Display
In normal operation the Minus button will toggle between the available displays while the Plus button will
activate special features of that display. The Enter button will activate the menu system.
Temperature Status & Power Output
This display shows the current temperatures from probe. If an error occurs a description will be shown instead
of the output information. The setting the device is trying to achieve is in parentheses. When ramping is
enabled for temperature the value in parentheses will change according to the time based curve.
Special Symbols:
Next to the number of the output an arrow symbol will appear if that output is currently in a ramping session. A
right arrow (
→
) will appear if the ramp is increasing. A left arrow (
←
)
will appear if the ramp is decreasing.
Next to the number of the output a minus sign (
-
) will appear if a Low Alarm has been breached. A plus sign
(
+
) will appear if a High Alarm has been breached.
High Low Status
This display indicates the highest and lowest temperature level recorded for the probe and the time at which it
was recorded. Pressing the + button will reset the High/Low to the current reading.
System Information
This display indicates the system time and the Power Outage Monitor. On power up a flashing character
showing S-
C will show next to the time as a reminder that the clock needs to be reset.
Each time the Herpstat
is powered on it increments the Power Outage Monitor. To reset the monitor to zero press the + button.
This display indicates the current time schedule the output is adhering to.
If the NiteCycle is disabled on the
output it wi
ll always show Day Cycle. If the
output's mode is set to disabled then it will also show disabled here.