Thank you for choosing the Herpstat 4 digital proportional thermostat.  This product 

offers the following features: 

 

 

Four output proportional heating constantly monitors and adjusts amount of heat necessary to 

maintain a target temperature (usable range from 40˚F to 150˚F or 4˚C to 65˚C).  

 

 

Outputs 1 & 2 configurable for Heating/Cooling/Lighting.  Outputs 3 & 4 can be configured for 

Heating /Cooling/Humidity/Lighting with simulated sunrise/sunset and moonlight features. 

 

 

User selectable temperature and light ramping. 

 

 

Sensor Matching allows the user to digitally calibrate the sensor output to match other equipment. 

 

 

Auto Power Matching constantly adjusts the power output curve to match the enclosures efficiency. 

 

 

Basking assist feature supports basking lights as a heat source. 

 

 

Individually selectable day/night schedules with nighttime temperature settings for each output. 

 

 

High/Low temperature tracking helps monitor heating system and enclosure efficiency. 

 

 

Individually selectable High/Low temperature threshold alarms. 

 

 

Precision temperature sensors with an internal resolution of .1125 ˚F and are accurate to ± .9 ˚F 

 

 

Display and setting in tenths of a degree. 

 

 

Security Passcode option deters vandals.   

 

 

All settings are retained in memory even if power is lost. 

 

 

Power Outage detection/tracking. 

 

 

Temperature can be set/displayed in Fahrenheit or Celsius. 

 

 

Easy to read backlit LCD display. 

 

 

Removable sensors allow for easy replacement if necessary. 

 

 

Each output is fused separately keeping an outage on one output from affecting the other. 

 

 

Audible alarm system 

 

 

Internal error detection shuts off heat if sensor fails or is disconnected. 

 

 

Internal safety relay can be configured to disable power to all outputs if user settable conditions are 

met. 

 

 

External input can be used to trigger events such as turning off a mist pump when the water supply 

is low. 

 

 

400 watt rating for each output (1600 watts total output) is sufficient for most incubators, rack 

systems, enclosures, and vivariums. 

 

 

1 year limited warranty 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Herpstat 4

Page 1: ...tput High Low temperature tracking helps monitor heating system and enclosure efficiency Individually selectable High Low temperature threshold alarms Precision temperature sensors with an internal resolution of 1125 F and are accurate to 9 F Display and setting in tenths of a degree Security Passcode option deters vandals All settings are retained in memory even if power is lost Power Outage dete...

Page 2: ...djust the settings Grounded outlets 3 prong plugs were added to accommodate more types of heating devices Basking assist feature added supports basking lights as a heat source Typically a proportional thermostat reduces power when the temperature is close to the target temp and turns off when the target temperature is breached This causes a strobing effect when using basking lights Basking assist ...

Page 3: ...rol continued DayTemp The DayTemp setting is the temperature the device will try to maintain during the Day Cycle If the Nite Cycle is disabled then the Day Temp setting will be used for the full 24hrs SnsrAdj The SnsrAdj Sensor Adjust setting is used to alter the temperature read by the temperature probe to match other equipment Note The sensor used in the Herpstat Probes are typically more accur...

Page 4: ...ntinued RH Note Only available in Humidity Sensed or Humidity Hybrid modes This setting adjusts the highest level of relative humidity Once this amount has been breached the power will shut off to the output Schedule Menu Enter this menu to set the scheduled times to activate a humidity session Note Only available in Humidity Scheduled or Humidity Hybrid modes In this menu use the Plus and Minus b...

Page 5: ... an error condition This also controls the built in safety relay Once the error condition is corrected the device will return to normal operations Options INDIVIDUAL OUTPUTS Excludes High Low This option is the default setting and does not enable the built in safety relay During an error condition it turns off the output that has the error High Low alarms will not shut off the output INDIVIDUAL OU...

Page 6: ...se clips and replace with a new fuse Do not use any fuse with a rating higher than 3 5 amps Reassemble the unit and test that the outputs are working properly before putting back into service Should the device not work as expected it s possible one of the menu settings was set incorrectly It may be easier to reset the device to its factory default settings than to figure out which setting is causi...