background image

Trip-L-Trap®

Automatic Condensate Drains
Models 505 and 506

F OR M N O.: 4011237    R EVI S I ON: 04/2014

R EAD AN D U N D E R STAN D TH I S MAN UAL PR I OR TO OPE RATI N G OR S E RVI CI N G TH I S PR OD U CT.

I N STR U CTI ON MAN UAL

Model 505

Model 506

Summary of Contents for Hankison Trip-L-Trap 505

Page 1: ...tic Condensate Drains Models 505 and 506 FOR M NO 4011237 R EVI S ION 04 2014 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT I N STR UCTION MAN UAL Mo...

Page 2: ...CONTENTS I GENERAL SAFETY INFORMATION 1 II DESCRIPTION 1 III INSTALLATION 2 IV ENGINEERING DATA 3 V OPERATION 3 VI MAINTENANCE 4 VII REPLACEMENT PART NUMBERS 7 VIII TROUBLESHOOTING GUIDE 8 WARRANTY 9...

Page 3: ...R FILTER I GENERAL SAFETY INFORMATION CAUTION A Pressurized devices This equipment is a pressure containing device Do not exceed maximum operating pressure as shown on equipment serial number tag Make...

Page 4: ...condensate a Tubing min 3 8 O D or piping min 1 4 may be run from the drain connection 1 4 FPT to an adequate sump or floor drain preferably below the level of the drain b Do not put a valve in the dr...

Page 5: ...1140 cc min 68 4 liters hr 18 gallons hr 1140 cc min 68 4 liters hr 18 gallons hr 9084 cc min 544 8 liters hr 144 gallons hr 9084 cc min 544 8 liters hr 144 gallons hr Drains are designed to operate...

Page 6: ...Remove retainer clip 36 and pivot pin 17 and lift float arm assembly 15 off of valve stem assembly 3 e Remove pilot valve screw assembly 18 from float arm assembly and replace with a new assembly from...

Page 7: ...sitioned in open area of seal ring retainer For models 506 506BC and 506HP make sure rod on top of float assembly fits into hole in seal ring retainer as shown in Figure 6 Detail D n Before reassembli...

Page 8: ...37 30 12 38 21 36 21 36 37 VENT LINE CONNECTION BOTTOM CONNECTION MODELS ONLY MODELS 506 506HP 506BC 506BCHP MODELS 506SS 506SSHP 506SSBC 506SSBCHP STANDARD MODELS STAINLESS STEEL MODELS PISTON ASSEMB...

Page 9: ...CSS 506BC 506BCSS Models 505HP 505HPSS 506HP 506HPSS Models 505BCHP 505BCHPSS 506BCHP 506BCHPSS Shell Case assy Bottom Models 505 505SS 506 506SS Models 505BC 505BCSS 506BC 506BCSS Models 505HP 505HPS...

Page 10: ...essure 2 Air supply through inlet or vent line obstructed 3 Drain line obstructed 4 Valve body has been turned causing impairment of float movement 5 Worn seals 1 Increase line pressure above 10 psig...

Page 11: ...by the manufacturer Normal maintenance items requiring routine replacement are not warranted Unauthorized service voids the warranty and any resulting charge or subsequent claim will not be paid Produ...

Page 12: ...Street Canonsburg PA 15317 1700 U S A P 724 745 1555 F 724 745 6040 E hankison americas spx com www hankisonintl com Improvements and research are continuous at SPX Specifications may change without...