8
Figure 2: Main components of typical APV sanitary / hygienic plate heat exchanger.
1.
Head for
connections and clamping the plate pack
2.
Follower
for clamping the plate pack
3.
End support
for supporting the top and bottom bars
4.
Top bar
for carrying and guiding the follower and plate pack
5.
Bottom bar
for guiding the follower and plate pack
6.
Tie bars
for clamping the plate pack between head and follower
7. Flow plate (Figure 1)
8. Flow gasket (Figure 1)
9.
Nut
for tie bar
10.
Adjustable
or fixed
legs
11.
Connector grid
for additional fluid connector bosses
12.
Connector bosses