Technical Description
Part description
Material
To be disposed as
Blower housing and blower wheel
Nylon pa66
Rigid plastic
Screws and motor shaft
Stainless steel
Metal/Stainless steel
Motor kit
Electronic waste
Waste handling / material recycling
At the product’s end of life please dispose of the product according to applicable law. Where applicable
please disassemble the product and recycle the parts material.
Electrical connection
Wiring: Use stranded copper wire. For lengths up to 25 feet (7.62 m) from the power source use 2mm
2
(12 AWG) or 2.5 mm
2
(10 AWG) wire for 12V and 1.5 mm
2
(16 AWG) wire for 24V.
The pump must be installed according to ISO 10133 (Small craft - Electrical system - Extra low voltage
DC installation for continuous current). Note: The fuse must be ignition protected. The wire connections
must be sealed with a marine sealant or sealed cable connectors.
Note: Before installation with electrical control systems, check that equipment to be used is of sufficient
rated capacity to accept ampere draw of motor. Low voltage will cause motor to overheat.
Wiring dimensions
Max wire length in m*
Wire size
mm
2
3-280
4-550
4-750
4-1000
12V
24V
12V
24V
12V
24V
24V
1,5
6,2
21,7
2,4
7,5
4,6
3,2
2,5
10,5
36,8
3,7
14,5
2,3
7,6
5,4
4
16,5
57,8
5,7
20
3,5
12,5
8,7
6
25,5
8,3
30
5,2
18
13
10
14,2
8,5
30
22
16
22,5
13,8
35
25
21
* The wire length is the total distance from the battery to the fan and back to the battery.
It is recommended to use a relay to shorten the main leaders.
Suggested fuse sizes
Capacity
Volt Fuse
280 m
3
(163 cfm)
12V
5 Amp
24V
5 Amp
550 m
3
(324 cfm)
12V
15 Amp
24V
10 Amp
750 m
3
(441 cfm)
12V
20 Amp
24V
15 Amp
1000 m
3
(589 cfm)
24V
20 Amp