Installation and preparation start-up
KGE/EN (1711) 6.5
3.9
Direction of rotation
• The direction of rotation of the pump is indicated by an arrow; check whether the
direction of rotation of the motor is the same, by switching it on for a short time.
Immediately switch the motor off, if the direction of rotation is found to be wrong. To
change the direction of rotation switch L1 with L2 or L3. Refer to wiring diagram on
the motor. Single phase motors and combustion engines have a fixed direction of
rotation.
•
If this check required the removal of a protective guard, avoid contact with
the rotating parts.
The protective guard
must
be replaced after the check.