SPX FLOW HANKISON HF 12 Instruction Manual Download Page 10

8

Dimensions and Weights

Filter T

ype                                          

  HF(Grade)-

12

16

20

24

28

32

36

40

44

48

Replacement Element                             

 E(Grade)-

12 or 12S

16 or 16S

20 or 20S

24 or 24S

28 or 28S

32 or 32S

36 or 36S

40 or 40S

44 or 44S

48 or 48S

Nominal Air Flow

scfm @100 psig (m

3

/hr @ 7.0 bar) 

20 (35)

35 (60)

60 (105)

100 (170)

170 (290)

250 (425)

375 (640)

485 (825)

625 (1060)

780 (1325)

In/Out Connection                              

NPT or BSP

3/8, 1/2

3/8, 1/2

3/8, 1/2

3/4, 1

3/4, 1

1, 1-1/4, 1-1/2

1, 1-1/4, 1-1/2

2, 2-1/2

2-1/2

2-1/2

"A" in. (mm)

4.13 (105)

4.13 (105)

4.13 (105)

5.25 (133)

5.25 (133)

6.44 (164)

6.44 (164)

7.63 (194)

7.63 (194)

7.63 (194)

"B" in. (mm)

8.15 (207)

10.05 (255)

12.40 (316)

13.32 (338)

17.57 (446)

20.80 (528)

25.29 (642)

29.08 (739)

34.83 (885)

40.96 (1040)

"C" in. (mm)

6.40 (163)

8.59 (224)

10.97 (285)

11.74 (298)

15.99 (406)

18.98 (482)

23.47 (596)

26.83 (681)

32.58 (827)

38.71 (983)

"D" in. (mm)

3.00 (76)

3.00 (76)

3.00 (76)

3.50 (89)

3.50 (89)

4.00 (102)

4.00 (102)

4.00 (102)

4.00 (102)

4.00 (102)

W

eight lb. (kg)

4.14 (1.88)

4.5 (2.04)

4.7 (2.13)

6.3 (2.9)

6.9 (3.1)

10.2 (4.63)

11.3 (5.13)

28 (12.70)

33 (14.97)

38 (17.24)

Maximum W

orking Pressure

Housing - 300 psig, 21.1 kgf/cm

2

Models with Internal Drain or

Liquid level indicator - 250 psig, 17.6 kgf/cm

2

Housing - 300 psig, 21.1 kgf/cm

2

Models with Internal Drain or 

Liquid level indicator - 250 psig, 17.6 kgf/cm

2

Maximum Operating T

emperature

150°F

, 66°C

150°F

, 66°C

Head Material

Aluminum

Aluminum

Bowl Material

Aluminum

Aluminum

Liquid Level Indicator Material

Isoplast

Isoplast

NOTE:

  Dimensions

 and

 W

eights

 ar

for

 r

efer

ence

 only

. Request

 certified

 drawings

 for

 constr

uction

 purposes.

OUTLE

T

CLEARANC

E

FOR SERVICIN

G

CLEARANC

E

FOR SERVICIN

G

INLET

OUTLE

T

INLE

T

"A

"

"C"

"B

"

"D

"

1" (26mm

)

"A

"

"C"

"B"

"D

"

2.3" (58.4mm)

OUTLET

INLET

INLET

OUTLE

T

CLEARANC

E

FOR SERVICIN

G

"A

"

"C

"

"B"

"D

"

2.3" (58.4mm

)

CLEARANC

E

FOR SERVICIN

G

"A

"

"C

"

"B

"

"D

"

2.3" (58.4mm

)

HEX WRENCH

3.00 ACROSS FL

AT

S

Sizes HF(Grade) 12, 16, 20

Sizes HF(Grade) 24, 28

Sizes HF(Grade) 32, 36

Sizes HF(Grade) 40, 44, 48

Figur

3.3

Dif

fer

ential

 Pr

essur

e

Gauge

Figur

3.2

Summary of Contents for HANKISON HF 12

Page 1: ...ressed Air Filters Models HF grade 12 through HF grade 48 FOR M NO 4011203 R EVI S ION 10 2015 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT I N STR...

Page 2: ...patible with many flammable gases the following applica tion limitations must be considered Housing materials are slightly porous The prod uct must be used in a well ventilated area in the absence of...

Page 3: ...icator S Corrosion Proof Stainless Steel Element X External Drain Adapter M Filter Monitor Example A Grade 5 high efficiency oil removal filter with a capacity of 100 scfm and 3 4 NPTF connections int...

Page 4: ...eam 1 100 of water 2 000 aerosols 1 aerosols 6 Afterfilter downstream of a pressure swing heatless desiccant dryer Downstream of an Activated Carbon or Desiccant Tower 1 No liquid should be present at...

Page 5: ...EN Wall Mounting Bracket Top Cap Figure 1 1 C Piping 1 Before installing blow out pipe line to remove scale and other foreign matter 2 This unit has DRYSEAL pipe threads use pipe com pound or tape spa...

Page 6: ...ping For ease of service isolation and by pass valves are desirable In critical applications two filters installed in parallel may be necessary to avoid interruption of air sup ply Figure 1 4 D Drain...

Page 7: ...ck pressure drop across the filter 1 Pressure differential in excess of 6 psi 0 42 kgf cm2 pressure indicator in yellow area indicates that the filter sleeve or element should be replaced Refer ence p...

Page 8: ...band indicates that liquids are accumulating faster than they can be drained and that prefiltration is required 4 Grade 1 activated carbon filters a Adsorption capacity 1000 hours at rated capacity El...

Page 9: ...sleeve 3 Clean separator core with soap and water if necessary 4 Slide new filter sleeve over separator core and replace bottom cap and hand tighten bolt 5 Make certain o ring inside top of element i...

Page 10: ...102 4 00 102 4 00 102 Weight lb kg 4 14 1 88 4 5 2 04 4 7 2 13 6 3 2 9 6 9 3 1 10 2 4 63 11 3 5 13 28 12 70 33 14 97 38 17 24 Maximum Working Pressure Housing 300 psig 21 1 kgf cm 2 Models with Intern...

Page 11: ...im will not be paid Products repaired or replaced under warranty shall be warranted for the unexpired portion of the warranty applying to the original product The foregoing is the exclusive remedy of...

Page 12: ...th Avenue Ocala Florida 34474 5788 U S A P 724 745 1555 F 724 745 6040 E hankison americas spxflow com www spxflow com hankison Improvements and research are continuous at SPX FLOW Inc Specifications...

Reviews: