SPX Cooling Technologies Recold JW Series Engineering Data Download Page 3

Recold 

/

 JW Series 

Fluid Cooler 

Construction

 

3

The JW Evaporative Fluid Cooler is a ruggedly built unit constructed to provide many years of durable, 

dependable service with minimal maintenance requirements. Quality materials and workmanship are a key 

factor in meeting this objective. 

FAN MOTORS

Fan motors furnished as standard equipment are open 

drip-proof type suitable for outdoor service. Motors 

have a 1.15 service factor and are mounted on a 

heavy duty adjustable base located for easy access.

FAN GUARD SCREENS

All moving parts are protected with OSHA approved 

galvanized steel screens. Each guard is easily 

removed for access to the fan.

FAN SECTION

The centrifugal fan is 

forward curved, statically 

and dynamically balanced 

and constructed of 

galvanized steel. The fan 

housing has curved inlet 

rings for efficient air entry 

and discharge into the 

pan. Fans are mounted 

on a solid steel shaft 

coated to resist corrosion. 

Heavy duty, pillow block 

type, self-aligning ball 

bearings are located at 

each end of the fan shaft. 
No intermediate bearings are 

required
Extended lube lines are supplied as standard 

equipment to allow servicing bearings without 

removal of fan guard screens.

WATER CIRCULATION PUMP

The water circulation pump is a close coupled, bronze 

fitted centrifugal type with mechanical seal. Each 

pump is factory mounted and piped. Standard motor 

is open drip-proof suitable for outdoor service.

DRIFT ELIMINATORS

Eliminators are constructed of PVC assemblies in 

removable, easy to handle sections. Each section has 

a three break design allowing three changes in air 

flow and measure approximately 5 inches in depth. 

The use of durable PVC eliminates the corrosion 

problems associated with galvanized eliminators.

HEAT EXCHANGE COIL

Coil tube bundle is constructed of 

5

8

" copper 

tubing with stainless steel tube sheets 

and copper headers. The copper 

construction offers a 

noncorrosive coil for extended 

service life.

ACCESS DOORS

Large rectangular access 

doors are strategically 

located to provide access 

to both upper water 

distribution system and 

lower pan basin. The 

patented doors provide a 

complete air and water tight 

seal without the use of 

gaskets or fasteners

WATER MAKE-UP

Water make-up is provided 

by a solid brass float valve with arm 

and float ball installed in an external float 

b o x . This allows easy observation of the water 

operating level and maintenance of the valve with unit 

in operation.

Construction:

 The Evaporative Fluid Cooler sump pan is constructed of 300 stainless steel and casing panels 

are constructed of heavy gauge, G-235 galvanized steel. The sump pan and casing panels are flanged outward 

so that all the connecting fasteners are located outside the flooded section of the unit to help prevent leaks 

in the unit and provides a more permanent watertight joint. To provide further protection from corrosion, no 

welded joints are located below the water line. The unit is designed for a 30 psf on any projected area and ships 

in one piece on a minimum 6" high stainless steel channel base to help in handling and installation of the unit.

Summary of Contents for Recold JW Series

Page 1: ... Recold JW Series Fluid Cooler Engineering Data ...

Page 2: ... coil can be drained without regard to internal corrosion This must be considered with steel tubes that do not have internal protection RECOLD HYDROSPRAY Recold engineering has developed an exclusive water distribution system called hydrospray This unique system provides optimum water coverage of the heat transfer coil for maximum efficiency and virtual elimination of harmful scale problems that r...

Page 3: ...are constructed of PVC assemblies in removable easy to handle sections Each section has a three break design allowing three changes in air flow and measure approximately 5 inches in depth The use of durable PVC eliminates the corrosion problems associated with galvanized eliminators HEAT EXCHANGE COIL Coil tube bundle is constructed of 5 8 copper tubing with stainless steel tube sheets and copper ...

Page 4: ...91 2 713 4 6 115 173 8 2 1 2 1 note 3 21 2 1 JW70 1841 4 981 2 931 4 192 47 191 2 841 2 8 115 note 4 2 1 2 1 note 3 3 11 4 JW85 208 981 2 933 8 217 47 191 2 961 2 8 1391 4 note 4 2 1 2 1 note 3 3 11 4 JW100 221 1181 2 1001 2 225 67 191 2 80 10 1391 2 note 4 2 2 2 2 note 3 4 11 4 JW115 2451 2 1181 2 1001 2 249 67 191 2 104 10 1641 2 note 4 2 2 2 2 note 3 4 11 4 JW130 269 1181 2 1001 2 273 67 191 2 ...

Page 5: ...me gal JWH Coil Face Area sq ft Circuits Connection OD Circuits Connection OD Circuits Connection OD JW10A 10 2 2 5 8 43 21 2 2 5 8 16 9 7 JW10B 21 2 2 5 8 43 42 2 2 5 8 20 9 7 JW10C 21 2 2 5 8 43 42 2 2 5 8 24 9 7 JW15B 26 2 3 1 8 64 52 2 3 1 8 31 14 5 JW15C 26 2 3 1 8 64 52 2 3 1 8 37 14 5 JW25A 33 2 3 1 8 95 66 2 3 1 8 37 21 6 JW25B 33 2 3 1 8 95 66 2 3 1 8 47 21 6 JW25C 33 2 3 1 8 95 66 2 3 1 ...

Page 6: ...at load on the coil at all time so that the leaving water temperature does not drop below 50 F Full flow alone will not protect the coil Temperature of 50 F must also be maintained Methods of maintaining the recommended fluid temperature may vary with system design and operation A simple means of preventing heat loss may be to locate the unit indoors allowing a heated atmosphere Adequate space and...

Page 7: ...election is therefore a JW35C 6 Determine Coil Pressure Drop Enter the Coil Pressure Drop Table at 225 GPM and read across to the unit model column to select pressure drop reading In this example pressure drop equals 4 8 PSI ETHYLENE GLYCOL EXAMPLE Select a unit to cool 75 GPM of 40 by volume ethylene glycol from 107 F to 85 F with 78 F wet bulb 1 Determine Range 107 F 85 F 22 F Range 2 Determine ...

Page 8: ...1 9 2 2 2 4 2 7 2 9 3 0 3 2 3 3 3 4 3 6 3 7 3 9 4 0 4 1 4 2 4 3 68 WET BULB RANGE 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 APPROACH 7 4 4 4 9 5 1 5 7 6 1 6 4 6 6 6 9 7 0 7 2 7 4 7 5 7 6 7 8 7 9 8 4 0 4 6 5 0 5 4 5 7 6 0 6 2 6 5 6 6 6 8 7 0 7 1 7 2 7 4 7 5 7 6 7 7 9 3 7 4 3 4 7 5 1 5 4 5 6 5 9 6 1 6 3 6 5 6 6 6 8 6 9 7 1 7 2 7 3 7 5 10 2 9 3 5 4 0 4 4 4 8 5 1 5 3 5 6 5 7 6 0 6 1 6 3 6 5 ...

Page 9: ...8 2 9 3 0 3 2 3 3 3 4 3 5 3 6 3 7 3 8 30 1 1 1 4 1 6 1 8 2 0 2 2 2 4 2 5 2 7 2 8 2 9 3 1 3 2 3 3 3 4 3 5 3 6 3 7 80 WET BULB RANGE 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 APPROACH 7 2 9 3 5 4 1 4 5 4 8 5 1 5 4 5 7 5 9 6 1 6 2 6 4 6 6 6 7 6 8 7 0 7 1 7 2 8 2 7 3 3 3 8 4 2 4 5 4 8 5 1 5 3 5 5 5 7 5 9 6 1 6 2 6 4 6 5 6 6 6 8 6 9 9 2 5 3 0 3 5 3 9 4 3 4 5 4 8 5 0 5 2 5 4 5 6 5 7 5 9 6 1 6 ...

Page 10: ...82 221 174 161 140 113 92 76 64 55 48 42 JWH 426 550 50A JWL 50 149 685 515 390 300 235 185 170 147 118 97 80 68 58 51 45 JW 150 550 50B JWL 50 149 JW 150 425 720 550 425 330 260 209 192 167 135 110 92 77 66 57 50 JWH 426 650 50C JWL 50 149 JW 150 425 760 585 455 355 281 225 207 181 147 121 101 85 72 63 55 JWH 426 650 70B JWL 70 209 JW 210 690 880 705 550 430 340 270 248 215 175 143 118 100 85 74 ...

Page 11: ... 6 6 3 8 1 7 1 8 9 4 4 6 0 5 4 7 3 6 5 8 6 180 6 7 7 8 4 5 5 3 2 5 3 2 3 9 2 2 2 7 3 2 1 9 2 4 2 8 7 0 8 9 7 8 9 8 4 9 6 6 6 0 8 0 7 1 9 4 190 7 4 8 5 5 0 5 9 2 8 3 5 4 2 2 4 3 0 3 5 2 2 2 6 3 2 7 6 9 8 8 6 10 7 5 3 7 3 6 5 1 3 7 8 10 3 200 8 0 9 3 5 4 6 4 3 1 3 9 4 6 2 6 3 2 3 9 2 4 2 9 3 5 8 2 10 5 9 4 11 7 5 7 7 9 7 0 1 7 1 4 1 8 225 10 1 11 6 6 7 7 9 3 8 4 8 5 8 3 2 4 0 4 8 3 0 3 6 4 3 2 0 2 4...

Page 12: ...r should be wired into the field control system to allow the dampers to fully open when the fan cycles on and close when the fan cycles off The actuator requires a 115V power supply ELECTRONIC WATER LEVEL CONTROL The electronic water level control package provides a constant and accurate means of monitoring water level in the unit For this reason it is often recommended for those installations whi...