SPX Cooling Technologies Cooling Tower MD-08F Brochure Download Page 3

Unmatched reliability

Heavy-duty construction,  
high-performance design and our  
five-year mechanical warranty ensures 
consistent, ctI-certified, fully rated 
cooling over a wide range of flow and 
temperature requirements.

Smaller footprint

Induced draft counterflow design 
requires less plan area than  
crossflow towers. And because  
the tower’s size results in less steel  
used, its reduced weight requires  
less support structure.

Ease of maintenance

SPX has worked hard to address  
the maintenance difficulties long 
associated with counterflow towers. 
our Md tower provides larger access 
doors, easily removable block fill 
and other features that simplify 
maintenance. For European towers, 
an optional fill removal access door is 
now available that complies with HSE 
AcoP L8 requirements.

Low energy consumption

Induced draft counterflow equipment 
minimizes the energy consumption 
by providing lower fan energy than 
centrifugal fan counterflow units.

Low-noise

the Marley Md comes standard  
with our ctI-certified low-noise fan, 
suitable for most noise-sensitive 
situations.

Marley MD Cooling Tower:  

The Right Answer in So Many Ways

Superior Water 

Management

to address the “splash-out” 
problem typically found in 
competitive counterflow 
designs, SPX introduces an 

industry first

: a triple-pass 

inlet louver and drift eliminator 
that conserves water and 
improves winter operation.

Summary of Contents for Cooling Tower MD-08F

Page 1: ...Introducing the Marley MD Cooling Tower The right answer in so many ways...

Page 2: ...ging it down to size The Marley MD is a packaged tower which makes it a definite go to solution for light industry and HVAC applications We re well known for our outstanding crossflow systems So why s...

Page 3: ...oors easily removable block fill and other features that simplify maintenance For European towers an optional fill removal access door is now available that complies with HSE ACoP L8 requirements Low...

Page 4: ...basin options are heavy gauge series 300 stainless steel Marley Geareducer Marley Geareducers decrease downtime and labor costs thanks to longer lasting fluid The suggested lubrication interval for ou...

Page 5: ...Triple Pass Louvers Fan Unit PVC Distribution System Triple Pass Drift Eliminators MC120 Fill...

Page 6: ...7 11 2565 2743 3912 234 15 2565 2743 3912 255 MD 5010 11 2565 3658 4013 293 15 2565 3658 4013 317 18 5 2565 3658 4013 341 22 2565 3658 4013 360 MD 5016 11 3607 3658 4851 368 15 3607 3658 4851 403 18 5...

Page 7: ...the Marley counterflow tower stand out from its competitors Triple pass inlet louvers and drift eliminator for superior splash out protection and water conservation SPX s position as sole source supp...

Page 8: ...ata layout requirements and more ask your Marley sales representative for a copy of the following publications Other SPX COOLING TECHNOLOGIES products SPX Cooling Technologies offers a full line of in...

Reviews: