SPT SF-610 Instruction Manual Download Page 3

   

 

2

 
A

PRODUCT INTRODUCTION 

 

The Evaporative Air Cooler is capable of providing various types of airflows: 

quiet and soft air like the spring breeze; fresh air simulating the Coastal breeze; 
cool, damp air like after a rainfall. 
 

 

 

The  different  type  of  airflows  will  accommodate  your  needs  to  provide  a 

comfortable  environment  and  reduce  the  heat  of  summer.  The  humidifying 
function will help keep your skin in good condition. The Ionizer feature cleans the 
air for a pure and clean breathing space. 
 

 

 

Thank you for purchasing SPT Evaporative Air Cooler. To have an in-depth 

understanding of the product and to ensure its proper usage, please read this 
instructions  manual  thoroughly,  especially  the  relevant  information  marked 
Warning and Caution. 

 

B

BRIEF INTRODUCTION OF FEATURES 

1.  High quality computer-controlled system. 
2.  Mechanical and full function remote control operation. 
3.  Features humidifier, air filter and Ionizer. 
4.  The composition of filter, water curtain and ionizer produces fresher air. 
5.  Supplies moisture to the environment in dry climates. 
6.  0.5 to 7.5-hour timer. 
7.  Ice compartment for extra cooling. 
8.  Oxygen Bar with Negative Ions: Negative ions have the effect of cleaning the 

air, providing you a clean healthy surrounding. 

9.  Three air modes and three fan speeds to select from. 
10. 120

 oscillating sweep angle cools maximum space. 

11. Energy efficient, input power of 60W. 

 
 

www.sylvane.com  1-800-934-9194

Summary of Contents for SF-610

Page 1: ...porative Air Cooler It is important that you read these instructions before using your new cooler and we strongly recommend that you keep in a safe place for future reference Model No SF 610 www sylva...

Page 2: ...BRIEF INTRODUCTION OF FEATURES 2 C CONTROL PANEL AND PARTS IDENTIFICATION 3 D OPERATING INSTRUCTIONS AND FUNCTIONS 4 E CARE AND MAINTENANCE 6 F CAUTION 7 G TECHNICAL PARAMETER 8 DEFECTIVE NOTICE 8 WAR...

Page 3: ...ure its proper usage please read this instructions manual thoroughly especially the relevant information marked Warning and Caution B BRIEF INTRODUCTION OF FEATURES 1 High quality computer controlled...

Page 4: ...t board Back cover Upper cover Front cover Short lamina Movable short lamina Long lamina Keystroke for opening Keystroke of function Panel Drain port Fig2 Wheel Front decorated board Water level glass...

Page 5: ...TIMER Press to set timer in increment of 5 hours from 0 5 to 7 5 hours Indictor lights that illuminate add up to the set time For example a timer of 7 hours will have the following indicator light on...

Page 6: ...r through the Water Inlet or through the side door Keep an eye on the Water Level Indicator and do not fill over the Maximum line Water level can also be noted through the side door The power supply s...

Page 7: ...e strong chemicals oil based products detergent chemically treated cloths or other strong cleaning solutions Filter 1 Slide filter upwards to remove 2 Clean with vacuum cleaner s brush attachment or w...

Page 8: ...the unit Do not obstruct the air outlet Keep a minimum space of 6 inches around the unit Fig 9 4 Suitable ambient temperature range is 40 F 100 F When temperature is high change water frequently to pr...

Page 9: ...N W 16 5 lbs Dimension 12 01 9 45 28 35 in DEFECTIVE NOTICE If this product is defective or not working properly Please DO NOT return to your retail store Please contact us directly with any Service o...

Page 10: ...will not be extended beyond the original one year period All replacement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use...

Reviews: