SPT RF-334SS Instruction Manual Download Page 4

2

 

 

2. 

INSTALLTION 

2.1 

Location 

When  selecting  a  position  for  your  unit,  please  make  sure  the  floor  is  flat  and  firm.  The  room 

should  be  well  ventilated  with  an  ambient  room  temperature  between  61°F  and  100°F.    Avoid 

locating your unit near a heat source, e.g. cooker, boiler or radiator. Also avoid direct sunlight as it 

may increase the electrical consumption. Extreme cold temperatures may cause the unit not to 

perform properly. This unit is not designed for use in garage or outdoor installation. Do not drape 

the unit with any covering.

  

Please  keep  a  clearance of 8  inches  on  both  sides,  6  inches  in  the rear  and  8  inches above the 

unit. This allows for proper air circulation around the refrigerator and improves the unit’s cooling 

efficiency. The door  can be opened to the  right or the left, depending on what better suits the 

location. Please ensure there is adequate space for the door to fully open. 

2.2 

Reversing the Door Swing 

Tools Required:

 

Phillips style screwdriver / Flat blade screwdriver / Hexagonal spanner 

 

We recommend that 2 people handle the unit for door reversal. 

 

Be sure the unit is unplugged and empty. 

 

Tilt the unit backwards and rest the unit on something solid so that it will not slip. Do not lay 

the unit flat on its back as this may damage the coolant system. 

 

Adjust the two leveling feet to their highest position. 

 

All parts removed must be saved for reinstallation of the door. 

 

1)  Remove the plastic covering from the top door hinge. 

 

 

2)  Unscrew the three screws from the bottom bracket. 
3)  Remove the foot from opposite side. 

 

4)  Place to one side. 

 

Summary of Contents for RF-334SS

Page 1: ...Instruction Manual 3 3 CU FT Refrigerator RF 334SS STAINLESS STEEL...

Page 2: ...Contents 1 SAFETY WARNINGS 1 2 INSTALLTION 2 3 PRODUCT OVERVIEW 4 4 OPERATION 5 5 CLEANING 6 6 MAINTENANCE 6 7 Trouble shooting 7 8 TIPS FOR ENERGY SAVING 7 9 DISPOSAL 8...

Page 3: ...ade by children without supervision 8 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 9 Please abandon...

Page 4: ...the refrigerator and improves the unit s cooling efficiency The door can be opened to the right or the left depending on what better suits the location Please ensure there is adequate space for the d...

Page 5: ...seals are closed on all sides before final tightening of the bottom hinge 12 Adjust the leveling feet as needed 2 3 Door Space Requirements The unit s door must be able to open fully as shown W D 35 5...

Page 6: ...to settle 2 7 Interior Accessories Various glass or plastic storage shelves are included with your appliance different models have different combinations In order to make the most of the storage volum...

Page 7: ...Most of these are perfectly normal but you should be aware of them These noises are caused by the circulation of the refrigerant in the cooling system It has become more pronounced since the introduc...

Page 8: ...located at the back of the unit and the adjacent components can be vacuumed using a soft brush attachment 5 3 Cleaning Tips Condensation may appear on the outside of the unit This may be due to change...

Page 9: ...g operation especially in summer this is caused by the radiation of the condenser and it is a normal phenomenon Condensation condensation may be detected on the exterior surface and door seals of the...

Page 10: ...refrigerant used in your unit and insulation materials require special disposal procedures Ensure that none of the pipes on the back of the unit are damaged prior to disposal Up to date information co...

Page 11: ...ement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only What is NOT COVERED Warranty does no...

Reviews: