![SPRT SP-POS76IV User Manual Download Page 16](http://html1.mh-extra.com/html/sprt/sp-pos76iv/sp-pos76iv_user-manual_1352039016.webp)
14
2.8 the printer parameter set
The function is to set up some simple parameters of the printer.
Enter the parameter setting method:
On shutdown condition, press the "MODE" button first, and then press
down the "FEED" button, and then open the power switch. After the status
indicators and PAPER OUT lights flash alternately, release the "FEED" button
.
Then press the "FEED" button twice, then release the "MODE" button. The
printer will be in parameter setting mode. And print out the first item can be set
parameters and its current value. Please see the appendix A part of the set
method in detail.
Exit the parameter setting method: Press the "MODE" button, and press
the "FEED"button, then loosen the "MODE" and "FEED" buttons, save the
setting values of the parameters and exit parameters setting MODE. Goes into
normal working mode
.
If directly close the printer power supply, the set of parameter values can
not be saved.
2.9 Enter into firmware upgrading MODE
On shutdown condition, press the "MODE" button, and press the "FEED"
button, and then open the power switch, after the light of status indicators and
PAPER OUT light flash release the "FEED" button. Then press the "FEED"
button five times, and then loosen the "MODE" button and then the print will be
into application upgrade MODE. Now the status indicator light flashes at the
speed of every 1 second.
Notice: when enter the upgrade mode, PAPER OUT light means the
interface can't be upgrade. At present, only a serial port and USB interface
support online upgrade program.
2.10 BID (Bi - direction) bidirectional printing adjust
Due to there is clearance between print head of mechanical transmission
gear and worm, may be after long time printing,the printing will not clear as
before.The BID adjustment function can solve the problem, specific operation
is as follows:
The first method:
1. open the "setting tool V2.03 L", find "print the BID adjustment test;Click "