8
The pin assignment of the cash drawer interface is as follows:
Pin No.
Signal
Direction
1
Chassis Ground
---
2
Cash drawer driver signal
Out
3
Cash drawer on/off status signal
In
4
+12V DC
Out
5
N.C
---
6
Cash drawer on/off status signal ground
---
2.3.5 Power Connection
SP-POS58VI uses external power supply as 12VDC±10
%
, 2A, one core model, as
below:
2.4 Buttons and Indicators
2.4.1 Power switch
Control on/off status of power.
is off status. Press “-” is on status.
2.4.2 Feed Button
【
FEED
】
is paper feed button. Print command can enable or disable
【
FEED
】
status
to be on or off. Under enable status, hold down
【
FEED
】
, start paper feeding, release the
button paper feeding stops.
2.4.3 Opening Upper Cover Button
Hold down opening upper cover button to open the case cover.
2.4.4 Power indicator light
If the power is on, the power indicator light will be on.
2.4.5 Status Indicator light and Buzzer
During normal working, red STATUS light is off. If the working status is abnormal, the
red indicator light will flicker to alarm error. Setting Buzzer can also alarm the abnormal
working status.
Light status
Buzzer status
Printer Working status
Off
Off
Normal