![SPRT SP-EU804 User Manual Download Page 23](http://html1.mh-extra.com/html/sprt/sp-eu804/sp-eu804_user-manual_1352027023.webp)
20
2, Press the button of
【
FEED
】
then open the power supply:
3,Close the rubber roller printing agencies, then print out three lines content as below:
Hexadecimal Dump
To terminate hexadecimal dump,
Press FEED button three times.
It is means the printer has enter into HEX printing mode, under this mode all the input
content will be printed out as HEX DUMP, the paper will online after press the
【
FEED
】
button
once, totally three times, print out "*** Completed ***", quit HEX DUMP mode.
2.8 The printer parameters setting
This function is to set up some simple parameters for the printer.
Enter into parameter setting method:
In shutdown mode, open the
【
printing rubber roller
】
first, press the button of
【
FEED
】
, then
open the power supply, after the status indicators and lack of paper lights flashing alternant
release the button of
【
FEED
】
. Press the button of
【
FEED
】
twice again, then close the
【
printing
rubber roller
】
. The printer enter into parameter setting mode. And print out the first item of
parameters and its current value which can be setted. The details for setting method reference
appendix A.
The method to quit the parameter setting
Open the
【
printing rubber roller
】
first, press the button of
【
FEED
】
, then close the
【
printing
rubber roller
】
and release the button of
【
FEED
】
, save the setting values of the parameters and
exit. Enter into the normal working mode.
If the printer’s power supply is closed directly, the setting parameters will lose.
2.9 Printer upgrade
the printer standby state, use the upgrade tool
‘
UpdateFirmware.exe
’
on the PC to perform
firmware upgrade.
Upgrade instructions:
1. In the standby state, select the port supported by the printer on the communication setting bar,
and then click.
2. In the Firmware File field, select the firmware file you want to download to the printer.
3. Finally click the Start Upgrade button.
After the printer upgrade firmware is completed, print the self-test test page i
Summary of Contents for SP-EU804
Page 7: ...4 SP EU804U SP EU804SU Standard model...
Page 8: ...5 SP EU804U SP EU804SU Optional positioning port...
Page 9: ...6 SP EU804UMF SP EU804SUMF Standard model...
Page 10: ...7 SP EU804UMF SP EU804SUMF Optional positioning port...
Page 11: ...8 SP EU805U SP EU805SU...
Page 12: ...9 SP EU805UMF SP EU805SUMF...
Page 15: ...12 SP EU805U SP EU805SU...
Page 16: ...13 SP EU805UMF SP EU805SUMF...