Heat pump installation notes

1)

The heat pump must be installed in open space. Normally is installed on the 
roof of house. 

2)

The unit should be placed in dry and well-ventilated environment. If the 
environment is humid, electronic components may get corroded or short circuit.

3)

Heat pump mustn’t be installed in the environment where corrosive, volatile, or 
flammable liquid or gas exists. 

4)

Because of the noise is a little loud, please don’t install the heat pump near 
bedroom or living room or meeting room. 

5)

The bottom of the heat pump should be at least 50cm higher than ground, 
because rain water, snow may enter inside if the installation is on ground. 

        Heat pump can be installed on concrete basic or steel support. 
6)

Please install a shed for the heat pump, otherwise, rain water can reduce the 
lifetime of the shell, and snow may cover the air outlet. 

7)

Water drainage ditch should be set around the heat pump, when heat pump is 
working, there is condensing water flow down, or when defrosting, there are 
plenty of water flow down too. 

8)

Heat pump should far away from kitchen exhaust, because the finned tube is 
not easy to clean if there is oil on it.

Summary of Contents for A22223

Page 1: ...Installation manual CGK C 22 380V 50Hz 3ph Product No A22223 Air source heat pump heating hot water PCB No CG248027 Operating panel No CG248028...

Page 2: ...Power supply wire line size must be selected according to this manual And must be grounded c Don t put in hands or stick to air outlet grill when fan motor are working d Don t use wet hand touch wire...

Page 3: ...Air inlet To know the product from exterior High pressure gauge Low pressure gauge Water outlet Water inlet Air outlet Electric box Cable hole...

Page 4: ...Important parts in heat pump T1 EVA T2 Fan T4 T1 T3 Filter G L COM...

Page 5: ...T6 T5 EEV 4WV CON Important parts in heat pump...

Page 6: ...port CN8 on PCB T4 Inlet gas temp sensor of compressor Connect to port CN9 on PCB T5 Environment air temp sensor Connect to port CN3 on PCB T6 Air heat exchanger coil temp sensor Connect to port CN6...

Page 7: ...Heat pump size 425 D N 2 5 DN25 1260 1260 1115 425 752 463 1115 485 117...

Page 8: ...er Hot water tank AC water tank Connect to city water T1 T2 Heat pump 3WV P1 P2 Floor heating Room thermostat Special valve for floor heating loop Water separator Water collector WFS F1 F2 F3 F4 NRV2...

Page 9: ...should be put in sensor tube which is installed in water tank like the drawing Introduction of the system 3 Heat pump circulating water pump P1 3 1 This water pump is controlled by heat pump controll...

Page 10: ...ter flow switch must be installed 6 2 Because factory hasn t install the water flow switch in heat pump so installed should install it outside heat pump 6 3 Water flow switch is controlled by heat pum...

Page 11: ...er tank is suggested to be pressured type 9 2 Water compensating pipe should be connected to city water And the valves must be opened In case there is leakage or after cleaned Y filter water reduced c...

Page 12: ...or living room or meeting room 5 The bottom of the heat pump should be at least 50cm higher than ground because rain water snow may enter inside if the installation is on ground Heat pump can be inst...

Page 13: ...2 Installation 2 4 Distances to barrier and ground 1 0 5 0 5 0 5 Top Right Left Ground 0 5 0 5 0 5 2 Top Back Ground Front...

Page 14: ...bolt 3 Before make basic or bracket please check heat pump dimension 4 Before fix heat pump on basic please confirm heat pump direction according to project design 5 Normally use expansion bolt to fix...

Page 15: ...ch High pressure switch Low pressure switch High water level Low water level S T Standby Standby floor heating Air HE coil Outlet gas Inlet gas Air Standby Current 4 way valve high pressure switch low...

Page 16: ...get electricity The terminal supply 220V 1ph voltage 2 Hot water valve When hot water side work 3 way valve coil loss electricity The terminal supply 220V 1ph voltage 3 Cycle water pump Rated current...

Page 17: ...itch on water pipe and connect the wire line to water flow terminals If don t install water flow switch please bridge connecting it 7 Room linkage It is ON OFF input signal dry contact At hot water he...

Page 18: ...Air HE coil Source side air heat exchanger coil temp sensor has been installed in heat pump Outlet gas outlet gas temp sensor of compressor has been installed in heat pump Inlet gas Inlet gas temp sen...

Page 19: ...Power supply terminal block A B C size 1 5mm2 N 1 5mm2 Y G 1 5mm2 Air circuit breaker 32A A B C N Yellow Green Red Blue Y G Y G Yellow Green Red Blue...

Page 20: ...stat to P2h the wiring diagram as below Wiring diagram of all room thermostat control water pump P2 AC 220V L N P2 L1 L3 L5 T2 T4 T6 L1 L3 L5 T2 T4 T6 L1 L3 L5 T2 T4 T6 AC 220V L N AC 220V L N Water s...

Page 21: ...eat pump only performs at hot water side when floor heating side no need can connect all room thermostats to Room linkage terminal 6 5 4 3 7 8 1 2 2 1 8 7 6 5 4 3 coil 2 and 7 input side connect 220V...

Reviews: