Model 340XRi / 680XRi / 1220XRi DC drive product manual HG102909 iss 9
1
This drive is an isolated 4 Quadrant speed controller for shunt wound or permanent magnet motors. It utilises
speed feedback from the armature voltage (Avf), or from a shaft mounted tachogenerator. It incorporates an
accurate current control loop to protect the drive and motor, and can be used in speed or current control
modes. The drive can operate in forward or reverse, motoring or regenerative braking.
Please obtain expert help if you are not qualified to install this equipment. Make safety a priority.
This
component is hazardous.
(
All specifications in this document are nominal).
340XRi 0.55KW (0.5 HP) at 180 Volts DC, 3.4 Amps
680XRi 0.75KW (1.0 HP) at 180 Volts DC, 6.8 Amps
1220XRi 1.80KW (2.0 HP) at 180 Volts DC, 12.2 Amps
Versions that work from 60V / 30V AC supply are also available.
340XRi / LV60, 680XRi / LV60, 1220XRi / LV60.
For motors rated up to 48V DC
Armature:
+/-200 Volts DC, or +/-50V for LV60 models.
Models 340XRi / 680XRi /1220XRi - 3.4/ 6.8/ 12.2 Amps.
Field:
Volts DC= 0.9 x AC supply volts. 1 Amp
(0.45 x AC for field connected to F- and N). 1 Amp.
110V AC or 240V AC +/-10%, 50–60 Hz.
30V AC or 60V AC +/-10%, 50-60Hz for LV60 models.
Speed range 0–100%. (motor dependant)
Load Regulation typically 0.2% tach, 2% Arm Volts.
Presets accessible under lift up cover.
Clockwise rotation for linear increase in parameter.
Relay driver threshold
(Level)
+/-(0.5% to 105%). (+/-10.5V) Symmetrical about zero.
Maximum Speed
(Max spd)
40V-200V span with Spd x 2 switch. (Avf/Tach fb volts)
LV60 models have an Avf range 10 - 50V.
Minimum Speed
(Min spd)
0 to 30% of maximum speed. (With 10K external pot).
Up Ramp
(Ramp )
20 to 1 seconds up ramp rate. (For 0 to +10V)
Down Ramp
(Ramp )
20 to 1 seconds down ramp rate (For +10 to 0V)
Stability
(Stab)
Gain 1 to 10
Maximum Current
(I max)
0 to 100% current limit.
IR compensation
(IR comp)
0 to 25%
Speed setpoint from
external 10K Ohms pot.
External RUN contact for electronic STOP/START.
Built in functions are+/- channel with pushbutton control inputs, and relay driver with variable
threshold. There is a pot kit available with graduated dial and knob. Sprint Electric part ref. POTKIT.
Speed loop: Full P+I armature voltage feedback.
Current loop: Full P+I isolated current feedback.
Use correctly rated cable minimum 600V AC, 1.5 times
armature
current.
DOC# HG102909 iss 9 07/11/05
Sprint Electric Limited, Arundel, UK
Tel.
+44 (0)1903 730000
Fax.
+44 (0)1903 730893
Email. [email protected]
www.sprint-electric.com
POWER RATING
MAXIMUM OUTPUT
AC SUPPLY INPUT
SPEED RANGE
USER ADJUSTMENTS
EXTERNAL CONTROLS
CONTROL ACTION
INSTALLATION